Bosch LTC 8600 Instruction Manual page 41

Allegiant microprocessorbased video switcher/control systems cpu firmware version 10.0
Table of Contents

Advertisement

LTC 8600 | LTC 8800 Series
F.01U.127.393 | 2.0 | 2009.03
1.
If using an Allegiant software package, attach the PC security key provided with
the software to an available port on the computer.
The supplied interconnect cable utilizes a custom pinout. If it ever becomes
necessary to replace the cable, it can be ordered separately using part number:
LTC 8506/00. Alternatively, a cable can be configured using the information
found in the Appendix Section of this manual.
2.
Attach one end of the supplied RS-232 interface cable to the main Allegiant
CPU bay connector marked Console (or another port that has been configured
to operate as a Console port).
3.
Attach the other end of the cable to an available serial port (COMM PORT 1 or
COMM PORT 2) on the rear of the computer.
4.
Apply power to the computer and allow it to boot up its operating system
before inserting the software disc.
5.
Refer to the applicable Allegiant software manual for complete programming
instructions.
6.
The communication settings of the PC must match those of the Allegiant. The
Allegiant communication settings can be changed using Keyboard User Func-
tion 30 (described later in this manual), or may have been previously set using
the Master Control Software. The factory default values are as follows:
Baud Rate
115200
Stop Bits
1
Data Bits
8
Parity
None
Instruction Manual
en | 35
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading