Position Of Connection Points; Address Selector Switch - Bosch Rexroth KMS02 Operating Instructions Manual

Indradrive mi distributed drive controller
Table of Contents

Advertisement

DOK-INDRV*-KMS02******-IT01-EN-P
Rexroth IndraDrive Mi Distributed Drive Controller KMS02
5.2.3

Position of Connection Points

5.2.4

Address Selector Switch

Figure
Fig.5-1:
Connection Points KMS02
WARNING
Before viewing the address, switch off power supply and wait until the 30-mi‐
nute discharge time has elapsed. Pull off the connectors form X103.1 and
X103.2 only thereafter.
Set the address for each KSM/KMS with the H and L rotary switches. The ro‐
tary switches are hidden under the X103.1 and X103.2 connector hoods.
Bosch Rexroth AG
Element Significance
H
Address selector switch
(10×)
L
Address selector switch (1×)
X37
Digital inputs/outputs
X38
X103.1
Hybrid cable
X103.2
X104
Motor encoder
X107
Programming module
X108
Communication output cou‐
pling (optional)
X109
X141
Safety technology (optional)
X156
Motor
Second connection point of
2.
equipment grounding con‐
ductor
High electrical voltage! Danger to life by elec‐
tric shock!
33/73
Instructions for Use

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth kms02.1b-a018

Table of Contents