cmd
arg1
add
-
pbayxy
dpsxyz
ispx
clkx
xbcx
cellx
3-38 Service Processor
Table 3-35 HC Subcommands (cont'd)
arg2
arg3
arg4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Description
Used to instruct the iSP to add components
manually. The management state of the iSP
changes from "nonexist" to "power-off".
Displays Help for "add" when the argument is
omitted or an error is made.
This subcommand can be executed in the AC
POWER ON state or DC POWER ON state.
When the Power Bay Unit is added, all partitions
must be in the DC POWER OFF state.
Adds a Power Bay Unit.
"x" is the cabinet number.
0: Main Cabinet
1: I/O Expansion Cabinet
"y" is the ID number within the cabinet.
0-2 for the Main Cabinet
0-1 for the I/O Expansion Cabinet
Adds DPS to the Power Bay Unit.
"x" and "y" are the same as described in "pbay"
above.
"z" is the number of Distributed Power Supply
Module (DPS) in the Power Bay Unit (0-5).
Adds an iSP Board.
"x" is the physical number of the iSP Board
(0 or 1).
Adds a CLK Board.
"x" is the physical number of the CLK Board
(0 or 1).
Adds an XBC Board.
"x" is the physical number of the XBC Board
(0-3).
Adds a CELL Board.
"x" is the physical number of the CELL Board
(0-7).