 Serial Port Configuration
There are two serial ports, (COM1 and COM2) in VT-IPSD102H. While COM1 port is fixed to
RS-232C, COM2 port can be set to RS-422 or RS-485 protocol.
The serial ports can be configured as follows.
Mode
Bitrate
Data Bits
Parity
Stop Bit
Each of the serial ports configurations must be same as connecting device.
 PTZ Configuration
PTZ Type
Select the type of PTZ camera or receiver.
PTZ ID
Since it is possible to control multiple PTZ cameras or receivers over single control line,
each camera or receiver will be assigned a unique ID. Enter PTZ ID of a camera or
receiver for control. The ID value range can be between 0 and 255.
PTZ Port
Select the serial port used for PTZ camera control.
 Sensor Type
There are two sensor input ports on VT-IPSD102H. Each of the sensor ports can be
configured to the following.
Function
OFF
NO (Normally
Open)
NC (Normally
Closed)
The function of the sensor port is set based on the type of the sensor connected.
 Sensor Schedule
Each sensor port can be enabled or disabled in day (of a week) and hour unit. Sensor is
disabled for grey-colored duration.
2400, 4800, 9600, 19200, 38400, 57600,
115200 bps
5, 6, 7, 8 bits
NONE, EVEN, ODD bit
1, 2 bit
Operation
Not used
The port is normally open and activated when
closed.
The port is normally closed and activated
when opened.