Cord Sets And Connectionplugs; Vac, 20 Amp, Duplex Receptacle; 120/240 Vac,30 Amp Receptacle; How To Usethe Generator - Generac Power Systems GP Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

2.3 CORD SETS AND CONNECTION
PLUGS
2.3.1 120 VAC,20 AMP,OUPLEX RECEPTACLE
This is a 120 Volt outlet protectedagainst overloadby a 20 Amp
push-to-reset circuit breaker (Figure8). Use each socket to power
120 Volt A0, single phase, 60 Hz electrical loads requiring up to a
combined 2400 watts (2.4 kW) or 20 Amps of current. Use only
high quality, well-insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
Keep extensioncords as short as possible, preferably less than
15 feet long, to preventvoltage drop and possible overheating of
wires.
Figure 8 - 120 Vo/t AC, 20 Amp, Duplex Receptacle
D
2.3.2 120/240 VAC,30 AMP RECEPTACLE
Use a NEMA L14-30 plug with this receptacle (rotate to lock!
unlock). 0onnect a suitable 4-wire grounded cord set to the plug
and to the desiredtoad. The cord set should be ratedfor 250 Volts
AC at 30 Amps (or greater)(Figure9).
Figure 9 - 120/240 VAC, 30 Amp Receptacle
12OV/24OV
3CA
2.4 HOW TOUSE THE GENERATOR
If there are any problems operatingthe generator,pleasecall the
generatorhelplineat 1-888-436-3722.
_t
ever operate in an enclosed
area or indoors!
NEVER use in the home, in a vehicle, or in
partly enclosed
areas such as garages,
EVEN
iF doors and windows are open! ONLY use
outdoors and far from open windows,
doors,
vents, and in an area that will not accumulate
deadly exhaust.
_t
The engine exhaust fumes contain carbon
monoxide,
which can you cannot see or smell.
This poisonous gas, if breathed
in sufficient
concentrations,
can cause unconsciousness
or
even death.
,_Adequate,
unobstructed flow of cooling and
ventilating air is critical to correct generator
operation. Do not alter the installation
or permit
even partial blockage
of ventilation provisions,
as this can seriously affect safe operation
of the generator. The generator MUST be
operated outdoors.
This exhaust system must be properly
maintained. Do nothing that might render the
exhaust
system unsafe or in noncompliance
with any local codes and/or standards.
,_t
Always use a battery operated carbon
monoxide
alarm indoors, installed according to
the manufacturers instructions.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator
exhaust contains carbon monoxide.
This is
a poison you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
Use this receptacleto operate120 Volt AC, 60 Hz, single phase
loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps or
240 Volt AC, 60 Hz,single phase loads requiringup to 7200 watts
(7.2 kW) of power at 30 Amps. The outlet is protectedby two 30
Amp push-to-resetcircuit breakers.