Magnum 8000X Mixed-Media Fiber Hubs
To determine whether a prospective network topology adheres to the collision
domain diameter specification, the following formula should be applied to the worst
case path through the network. The worst case path is the path between the two Fast
Ethernet devices (DTEs) which have the longest round-trip time.
PDV = (sum of cabling delays) + (sum of repeater delays) +
PDV is the Path Delay Value of the worst case path. For the network to
adhere to IEEE standard, this value must be less than 512 BT. The safety margin is
specified in BT and may be a value between 0 and 5. This margin can be used to
accommodate unexpected delays such as extra long patch cable. A safety margin of
about 2 to 4 BT is recommended.
A typical example of a PDV calculation is shown below, and is illustrated in
Figure 3.6.1a. Here, an integrator wishes to cascade the 100Mbps collision domains of
two Magnum 8000X Mixed-Media Hubs (each having a PDV of 80 BT) for use with
standard 100m Category 5 user cable segments (i.e. from computer to hub) and needs to
know how long the inter-repeater Category 5 cable segment, used to cascade the hubs,
can be. The variable "X" represents the unknown maximum cascade cable delay.
PDV = X + ((111 + 111) + (80 + 80) + (100) + 2 ) BT < 512 BT
512 > (X + 486) BT
X
< (512 - 486 ) BT, X < 28 BT
Twisted Pair cable length, TL < (28 BT) / (1.112 m/BT)
TL
< 25 meters
25 m maximum total length for Category 5 inter-repeater segment,
where 111 is the BT delay for 100m of Category 5 cable (1.112 BT/m* 100m), 80 is the
BT delay for each Magnum 8000X , 100 is the BT delay for the TX DTE pair, and a
safety margin of 2 was used. Figure 3.6.1a: Two cascaded Magnum 8000X hubs
.
.
www GarrettCom com
(DTE pair delay) + (safety margin)
Cat. 5 cable for
cascading
PWR BRD
Mag num 8000X
R L S
R L S
R L S
R L S
R L
R L
R L
R L
R L
R L
R L
R L
R L
Mixed Med i a Hu b
1
10 100
ACT
COL
GAR RETT
100 m Cat. 5 cables
to user devices
Installation and User Guide (05/ 02)
PWR BRD
Magnum 8000X
R L S
R L S
R L S
R L S
R L
R L
R L
Mixed Media Hub
1
10 100
ACT
COL
GA R RE TT
R L
R L
R L
100 m Cat. 5 cables
to user devices
25
R L
R L
R L
R L
R L
R L
R L
R L
R L

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum 8000x-a

Table of Contents

Save PDF