Clearances; Electrical And Water Connection Location - Monogram ZIRS36N LH Installation Instructions Manual

Stainless steel 36" built-in refrigerators and freezers
Hide thumbs Also See for ZIRS36N LH:
Table of Contents

Advertisement

Installation Preparation
36" Stainless Steel Refrigerators,
Freezers
Clearances
Min. to
130° Door
Wall
Swing
""130 °
"_{':')
, 90° Door Swing
,.
[__
i,
J i36-3/4"
'\\
.......
--1 ,"._
4"_Min.
to Wall
Factory set for a 130° door swing. Order WX14X99
adjustable door stop to reduce swing to as little
as 90 °.
When
Installed
into a corner:
Allow 25" for a full 130 ° door swing. Allow 15" for pan
removal.
Allow 4" min. clearance
when door swing is
adjusted
to a 90 ° opening
for pan access, but pan
removal
is restricted.
--25"
H
Min. to
130° Door
130° Door
Wa
Swing
Swing
,,1
I I
//
1-'
'-r
:::!:::::i::x ,,"
,/
"--.
........
j/j
25 _'_
Min. to
Wall
[,,
Clearances
for Multiple
Single Door Installations
In a side-by-side
installation
of a left and right door
swing product,
no clearance
between
the units is
required.
Order ZUGSS Stainless
Steel Unified Grille
Panel Kit for one continuous
grille panel.
2"
H
_15'%
•)\ !
J\
• ','-[
\\ '\
\\
\\
\,'\
,
\\ %
"'..
.;,_: "-..
.;,,_
Clearances
for two products
installed
side-by-side
with
the same (left or right)
door swing
Allow 2" minimum
clearance
between
the products
to prevent
door swing interference.
Order the
WX14X99
adjustable
door stop to reduce the factory
set 150 ° door swing. Allow 15" minimum
to a wall to
achieve
full drawer
extension
and pan removal.
NOTE: ZUGSS Grille Panel Kit will not fit this
installation.
5"
!
'\/'
!
'-i
\v:':,i'
]"
A A
/
////'\
\
/
/ /
\ ',,
/
'_
, //'//
\,'\\,
jJ
Clearances
for two products
installed
side-by-side
with
right
and left side hinges
together
Allow 5" minimum
between
the two products
to
prevent
one door from striking
the othen Use the
WX14X99
adjustable
door stop to reduce the factory
set 130 ° door swing and to allow pan removal.
NOTE: ZUGSS Grille Panel Kit will not fit this
installation.
Electrical
end Water
Connection
Locations
The water
line can be routed
through
the floor or
back wall.
• The icemaker
water
line should
be:
- Approximately
3-1/2"
from the floor on the back
wall, or 3-1/2"
from the back wall on the floon
- At least 5" from either side of the opening.
A 115 volt, 60 Hz 15 or 20 amp power supply
is
recommended.
An individual
properly
grounded
branch
circuit
or circuit
breaker
is recommended,
as noted on the rating
plate.
• Locate the electrical
outlet within
5" x 6" shaded
area shown.
- 2-1/2"
from the left side.
Between
75" and 81" from the floon
IMPORTANT: To insure a flush fit and access to the
power cord, locate the electrical
outlet as shown.
Electrical Outlet
Location 2-1/2"
y6I
Water Supply
|
3-1/2" / \ 3-1/2"|
3-1/2"
75"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zirs36n rhZifs36nZifs36n rh

Table of Contents