Kenmore HE 4 Use And Care Manual page 9

He 4/he 5 series electric dryer
Hide thumbs Also See for HE 4:
Table of Contents

Advertisement

Available languages

Available languages

Electrical Connection Options
If your home has:
And you will be
Go to Section
connecting to:
4-wire receptacle
A UL listed,
4-wire connection:
(NEMA Type 14-30R)
120/240 volt
Power supply cord
minimum,
30 amp, dryer
power supply
cord*
4-wire direct
A fused
4-wire connection:
disconnect
or
Direct Wire
circuit breaker
box*
3-wire receptacle
A UL listed,
(NEMA type 10-30R)
120/240 volt
minimum,
30 amp, dryer
power supply
cord*
3-wire connection:
Power supply cord
3-wire direct
A fused
3-wire connection:
disconnect
or
Direct Wire
circuit breaker
%!;_m_
box*
*If local codes do not permit the connection of a frame-grounding
conductor to the neutral wire, go to "Optional
3-wire Connection"
section.
4-wire connection:
Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
A
C
D
F
E
G
A. 4-wire receptacle
(NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
E 3_. (1.9 cm) UL listed strain relief
G. Ring terminals
1. Remove center terminal block screw.
2.
Remove neutral grounding wire (green with yellow stripes)
from external ground conductor screw. Fasten it under center,
silver-colored
terminal block screw.
A
A. External ground conductor
screw - Dotted line shows
position of NEUTRAL grounding
wire before being
moved to center terminal block screw
B. Center silver-colored
terminal block screw
C. Green/yellow
wire of harness
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor
screw. Tighten screw.
4. Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block.
B
A, External ground conductor
screw
B, Ground wire (green or bare) of power supply cord
C. ¾" (1.9 cm) UL listed strain relief
D. Center silver-colored
terminal block screw
E. Neutral grounding
wire (green with yellow stripes)
E Neutral wire (white or center wire)
5. Connect the other wires to outer terminal block screws.
Tighten screws.
6. Tighten strain relief screws.
7.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down
screw.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

He 5 110.8586110.8587 series110.8586 series4

Table of Contents