This dryer can be converted to exhaust out the right side, left
side, or through the bottom. Contact your local dealer to have the
dryer converted.
Fire Hazard
Cover unused exhaust holes with one of the
following kits:
279818 (white)
279915 (graphite)
279925 (biscuit)
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5" (12.7 cm) mismatch
Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch
Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
A
C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation (Not an option
with pedestal installations.)
Alternate
installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance
installations are shown.
Refer to the manufacturer's
instructions.
_=====-
-
,,
--==_,_-
//
//
I
I/
A
B
A. Over-The-Top installation (also available with one
offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information,
please call f-8OO-4-MY-HOME e (1-800-469-4663).
Over-The-Top Installation:
Part Number 26-49999
Determine
Vent Length
1o Select the route that will provide the straightest and most
direct path outdoors.
Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually
to avoid kinking. Avoid 99° turns when possible.
2.
Determine
vent length
The maximum
length of the exhaust
system
depends
upon:
The type of vent (rigid metal or flexible metal).
The number
of elbows used.
Type of hood.
Recommended
hood styles are shown here.
(10.2 cm)
(10.2cm)
A. Louvered hood style
B. Box hood style
The angled hood style (shown following) is acceptable.
_,_(.
)
13