Step
1
Attach the rackmount bars with the screws and brackets supplied in the rackmount kit.
2
To allow proper grounding, scrape the paint from the rack around the mounting holes where the
NetVanta will be positioned.
3
Position the NetVanta in a stationary equipment rack. This unit occupies 1U of space.
4
Have an assistant hold the unit in position as you install two mounting bolts through the unit's
brackets and into the equipment rack using a #2 Phillips-head screwdriver.
5
Apply power to the unit (refer to
Wall Mounting the NetVanta
By following these instructions exactly, the NetVanta can be safely mounted on the wall.
NetVanta units are to be installed only by qualified service personnel.
To avoid damaging the unit, use only the screws included in the shipment when
attaching mounting ears to the chassis.
When wall mounting the NetVanta, care must be taken not to damage the power cord.
Do not attach the power cord to the building surface or run it through walls, ceilings,
floors, or openings in the building structure.
The socket-outlet must be installed near the equipment and must be easily accessible.