Set-up
Operating manual 281 Version 06.0 - 05/2013
7.7 Controller
The machine is operated using the DAC BASIC controller with the
OP 1000 control panel.
7.7.1 Fitting the controller
Figure 34: Fitting the controller
(1) - Strain relief mechanism
1. Screw the controller (3) onto the four screw holders (2) under
the table plate.
2. Clamp the power cable for the controller into the strain relief
mechanism (1).
3. Screw the strain relief (1) under the table plate.
①
(2) - Screw holder
(3) - Controller
②
③
57