NEC HX4500 User Manual page 128

Hide thumbs Also See for HX4500:
Table of Contents

Advertisement

Table 5-1. POST Error Codes and Messages (cont'd)
Code Error message
0B16
Extended RAM failed
0B17
Failing Bits
0B1A Missing or Invalid NVRAM taken
0B1B PCI System Error on Bus/Device/Function
0B1C PCI Parity Error on Bus/Device/Function
0B1E Unsupported CPU detect.
0B1F
System Temperature is exceeded limit.
0B23
WARNING: CPUs with different L2 cache
size are found.
0B30
Fan 1 Alarm occurred.
0B31
Fan 2 Alarm occurred.
0B40
Invalid System Configuration Data - run
configuration utility
0B41
System Configuration Data Read Error
0B42
Resource Conflict
0B43
Warning: IRQ not configured.
0B44
Expansion Rom not initialized
0B45
System Configuration Data Write Error
BIOS not installed
Warning: The system detected on illegal CPU
Card combination.
A system error has occurred.
5-12 Problem Solving
Description
A memory error was detected.
A memory error was detected.
NvRAM value is illegal.
A error was detected on PCI bus.
A error was detected on PCI bus.
CPU step was incorrect.
An abnormal temperature was detected.
CPUs of different cache size were detected.
A failure on option slot fan was detected.
A failure on CPU fan was detected.
System configuration is illegal.
Read error of system configuration data.
Resource such as IRQ or memory conflicts.
IRQ conflicts.
Initialization of expansion ROM failed.
Write error of system configuration data.
No bootable device is found on Fast SCSI2
bus channel.
Combination of CPU cards is invalid.
An error occurred on system.

Advertisement

Table of Contents
loading

Table of Contents