Removing A Remote Supervisor Adapter Ii Slimline - Lenovo ThinkServer RD120 Hardware Maintenance Manual

Hardware maintenance manual for rd120
Hide thumbs Also See for ThinkServer RD120:
Table of Contents

Advertisement

1. Install the adapter in the expansion slot. The following illustration shows how to
2. If you removed the PCI riser-card assembly to install the adapter, install the PCI
3. Connect any required cables to the adapter.
4. Perform any configuration tasks that are required for the adapter.
5. Install the cover (see "Installing the cover" on page 57).
6. Slide the server into the rack.
7. Reconnect the external cables; then, reconnect the power cords and turn on the

Removing a Remote Supervisor Adapter II SlimLine

Note: Before removing a Remote Supervisor Adapter II SlimLine, create a backup
copy of the configuration so that if you are replacing the adapter, you can restore
the configuration.
To remove the Remote Supervisor Adapter II SlimLine, complete the following
steps.
install an adapter in a PCI slot on the riser card.
Note: For clarity, the riser-card assembly 1 is inverted in this illustration.
riser-card assembly (see "Installing the riser-card assembly" on page 64).
Attention:
v When you route cables, do not block any connectors or the ventilated space
around any of the fans.
v Make sure that cables are not routed on top of components under the PCI
riser-card assembly.
v Make sure that cables are not pinched by the server components.
peripheral devices and the server.
Attention:
In a dc power environment, only trained service personnel other
than Lenovo service technicians are authorized to connect or disconnect power
to the dc power supply. See the documentation that comes with each dc power
supply.
Chapter 4. Removing and replacing server components
67