Lenovo ThinkServer RD120 Hardware Maintenance Manual page 190

Hardware maintenance manual for rd120
Hide thumbs Also See for ThinkServer RD120:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
035-285-001
Adapter Communication Error.
035-286-001
Adapter CPU Test Error.
035-287-001
Adapter Local RAM Test Error.
035-288-001
Adapter NVSRAM Test Error.
035-289-001
Adapter Cache Test Error.
035-292-001
Adapter Parameter Set Error.
035-230-001
Battery Low.
035-231-001
Abnormal Battery Temperature.
035-231-001
Battery Status Unknown.
089-xxx-00n
Failed microprocessor test.
Note: n = APIC ID for failing
microprocessor
v 0, 1, 2, 3 = microprocessor 1
v 4, 5,6, 7 = microprocessor 2
Odd APIC numbers are hyperthreads.
172
ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual
Action
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
Replace the battery module on the ServeRAID SAS
controller.
Replace the battery module on the ServeRAID SAS
controller.
Replace the battery module on the ServeRAID SAS
controller.
1. Make sure that the BIOS code is at the latest
level.
2. (Trained service technician only) Reseat the
microprocessor.
3. (Trained service technician only) Replace the
microprocessor.

Advertisement

Table of Contents
loading

Table of Contents