Installing The Dimm Air Baffle - Lenovo ThinkServer RD120 Hardware Maintenance Manual

Hardware maintenance manual for rd120
Hide thumbs Also See for ThinkServer RD120:
Table of Contents

Advertisement

Installing the DIMM air baffle

To install the DIMM air baffle, complete the following steps.
1. Align the tabs on the sides of the air baffle with the slots on the power-supply
2. Place your fingers into the handle and opening on the top of the DIMM air
3. Press the handle toward the opening and lower the air baffle so that the lip on
4. Press the DIMM air baffle into place.
5. Install the cover (see "Installing the cover" on page 57).
6. Slide the server into the rack.
7. Reconnect the external cables; then, reconnect the power cords and turn on the
Attention:
the server. Operating the server with an air baffle removed might damage server
components.
62
ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual
1
DIMM air baffle
2
Riser card assembly
cage.
baffle.
the right side of the baffle covers the lip on the side of the power-supply cage.
peripheral devices and the server.
Attention:
In a dc power environment, only trained service personnel other
than Lenovo service technicians are authorized to connect or disconnect power
to the dc power supply. See the documentation that comes with each dc power
supply.
For proper cooling and airflow, replace the air baffle before turning on
3
Finger hole
4
Release ring