Dell PowerConnect W-IAP175P User Manual page 132

Instant access point
Hide thumbs Also See for PowerConnect W-IAP175P:
Table of Contents

Advertisement

Table 18
Type Code
100309
100410
100511
132 | Alert Types and Management
Alerts List (Continued)
Description
RADIUS server
authentication failure
Integrity check failure
in encrypted message
DHCP request timed
out
Details
The IAP cannot authenticate this client
using 802.1X because the RADIUS server
rejected the authentication credentials
(password, etc) provided by the client.
The IAP cannot receive data from this
client because the integrity check of the
received message (MIC) has failed.
This client did not receive a response to
its DHCP request in time.
Dell PowerConnect W-Instant Access Point 5.0.3.0-1.1.0.0 | User Guide
Corrective Action
Ascertain the correct authentication
credentials and log in again.
Check the encryption setting on the client
and on the IAP.
Check the status of the DHCP server in the
network.