To change the temperature display, press the Program Mode
display.
To toggle constant temperature display on and off, enter 1, 6, 5, 1,
constant temperature display mode, the countdown time will not be displayed.
To toggle between Fahrenheit and Celsius temperature display, enter 1, 6, 5, 8,
FBKR18 C
D
OMPUTER
SELP – Prompts you to select a product button for programming.
CodE – Prompts you to enter a sequence of numbers to change functions.
°-HI – Indicates that the water temperature is more than 3°F above setpoint.
°-Lo – Indicates that the water temperature is more than 3°F below setpoint.
- - - -
(four dashes) – Indicates that the water temperature is within the proper
rethermalizing range (i.e., within ±3°F of setpoint).
HELP – Indicates a heating problem. Call your local Frymaster Factory Authorized Service
Center or the 24-Hour Hotline (1-800-551-8633).
Prob – Indicates a problem in the temperature control circuits. Call your local Factory
Authorized Service Center or the 24-Hour Hotline (1-800-551-8633).
FBKR18 B
S
OIL OR
IMMER
Pressing the Boil Mode (L) switch overrides the programmed setpoint and the cookpot temperature
rises to boiling at 212°F (100°C). When the unit is in boil mode, boiL appears in both LED
displays. The unit remains in boil mode until the Simmer Mode switch is pressed or the unit is
turned off.
Pressing the Simmer Mode (R) switch causes the cookpot temperature to be maintained at the
programmed setpoint. If the cookpot temperature is above the setpoint,
LED widows. If the cookpot temperature is below the setpoint,
- - - -
(
) are displayed if the temperature is within 11°F (6°C) of setpoint.
FBKR18 C
S
LOCK
PEED
The computer can be programmed for either "standard" or "slow" rethermalizing times. The
standard clock displays minutes and seconds, the slow clock displays hours and minutes. To
toggle back and forth between times press the Program Mode
. To determine whether the clock speed is set to standard or slow, initiate a rethermalizing
cycle by pressing a product button. If the computer is set to the standard clock, the time in the
LED display will immediately begin to count down. If it does not, the computer is set to the
slow clock.
M
ISPLAY
ESSAGES
M
O
ODE
PTIONS
O
PTIONS
switch; CodE appears in the
°
-Lo is displayed. Four dashes
3-7
. NOTE: When in
.
°
-HI is displayed in both
switch, then enter 1, 6, 5, 3,