Hlz Computer Operation And Programming; Programming Temperature - Frymaster Heated Landing Zone HLZ 18 Service Manual

Frymaster heated landing zone service manual
Hide thumbs Also See for Heated Landing Zone HLZ 18:
Table of Contents

Advertisement

7. HLZ COMPUTER OPERATION AND PROGRAMMING

Heater Plate
Temperature
Switch (1)
ON/OFF Switch

7. 1 Programming Temperature

You are able to program the setpoint temperature of both the air heater and the heater plate
via the computer interface. The heater plate factory default is set to the McDonald's standard
of 160°F. The air heater factory default is set to the McDonald's standard of 220°F. If the
factory default temperature settings are acceptable, skip to Section 7.2, Page 6.
Ensure that the HLZ computer is in the OFF position (nothing in the display).
Press the check switch and enter the code (1,2,3,3). The numerals in the upper right-hand
corner represent the key number.
Press
The display will read SET and the LEDs on both the Heater Plate Switch (1) and the Air Heater
Switch (4) will light. Press the switch that corresponds to the heater you wish to program.
Frymaster L.L.C., 8700 Line Avenue 71106, P.O. Box 51000, Shreveport, Louisiana 71135-1000
Printed in the United States
Display
Down Switch (2)
, then
,
318-865-1711
Service Hotline
1-800-24-FRYER
Up Switch (3)
,
,
FAX 318-862-2394
Air Heater
Temperature
Switch (4)
Check or
Program Switch
in order
Page
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heated landing zone hlz 22Hlz 18Hlz 22

Table of Contents

Save PDF