Adjusting The Pilot Flame; Replacing Fryer Components; Replacing The Operating Thermostat - Dean Super Runner Series Service & Parts Manual

Super runner series & super marathon series dean millivolt gas fryers
Hide thumbs Also See for Super Runner Series:
Table of Contents

Advertisement

1.6 Adjusting the Pilot Flame

1. Remove the cover shown in the illustration below to access the pilot flame adjustment screw in
the gas valve.
Pilot adjustment locations on CE gas valves (left) and non-CE gas valves (right).
2. Using a small, flat-tipped screwdriver, turn the pilot flame adjustment screw counterclockwise to
increase the length of the flame or clockwise to decrease the length of the flame. Adjust the
flame to a length of 1-½ inches (38 mm).
3. Reinstall the pilot flame-adjustment cover.
4. Five-tube millivolt fryers: Adjust the trailing pilot (adjustment valve located on the burner
manifold) until a 1-½ inch (38 mm) flame is obtained.

1.7 Replacing Fryer Components

1.7.1 Replacing the Operating Thermostat

1. Drain the fryer and turn the gas off.
2. Remove the thermostat knob by pulling straight out on the knob with a firm, steady pull.
3. Disconnect the wires from the thermostat.
4. Remove the two mounting screws to release the thermostat control from its mounting bracket.
5. Remove the screws and clamp that secure the thermostat bulb to the frypot. Remove spring from
bulb and reinstall on replacement thermostat bulb.