2. At each scheduled boil-out, disassemble the leaf filter assembly and place in the frypot being
boiled out. Follow the boil-out procedure in Section 5.3.2 of this manual.
3. Allow all filter assembly components to air dry or thoroughly dry with clean towels before
reassembling.
Reassembly
1. Place the two outer screens together and align their edges (see illustration below).
2. Insert the screens into one of the frame halves (it doesn't matter which one). Ensure that the
fitting in the bottom screen is on the opposite side of the frame from the handle.
3. Slip the grid between the screens, ensuring that the grid is centered between the edges of the
screens.
4. Connect the other half of the frame at the corner opposite the handles and pivot the frame onto
the free edges of the screen.
Steps 1 and 2 - Stack outer screens
and insert edges into frame.
Handle
4.4

Draining and Disposing of Waste Oil

When cooking oil is exhausted, the oil must be drained into the filter pan, SDU or other appropriate
METAL container for transport to the disposal container or if a bulk oil system is installed, use the
bulk oil disposal system by selecting DISPOSE from the filter menu if the fryer is equipped with a
3000(see page 1-13 in the controller manual) and follow the prompts and instructions for disposing
oil to the bulk oil system. (For safe, convenient draining and disposal of used oil, Frymaster
recommends the use of the Frymaster Shortening Disposal Unit (SDU) for JIB systems. The SDU is
available through your local distributor.) NOTE: If using an SDU built before January 2004 the
filter pan cover must be removed to allow the unit to be positioned beneath the drain. To remove the
lid, lift up on the front edge and pull it straight out of the cabinet. Refer to the documentation
furnished with your disposal unit for specific operating instructions. If a shortening disposal unit is
Step 3 - Insert grid between screens
after screens have been positioned in
frame.
Step 4 - Connect corner then pivot
frame over free edges of screens.
4-6