of a split vat or full vat where the error occurred (example - E06R0 11:30 12/07/07).
Error Codes:
E01 - Right Remove Discard
E02 - Left Remove Discard
E03 - Probe Failure - Call Technician
E04 - Hi 2 Bad - Call Technician
E05 - Hot Hi 1 - Call Technician
E06 - Ignition Failure - Call Technician
(2) button (see Figure 159) two times to exit.
4. Press the
The computer displays OFF.
4.13.3 PASSWORD MODE
The password mode allows a restaurant manager to change passwords for various modes and levels.
1. Perform steps 1-3 on page 4-32.
Computer displays password.
(1 yes) button to accept selection (see Figure 160).
2. Press the
Computer displays password SETUP.
(1 yes) button to accept selection (see Figure 161).
3. Press the
Computer displays fryer setup.
4. Press the t and u buttons (see Figure 162) to scroll between:
a. FRYER Setup – Selects password to enter FRYER Setup
mode. (Default is 1234)
b. usage – Selects password to enter usage mode to reset usage
statistics. (Default is 4321)
c. level 1 – Selects password to enter level 1 mode. (Default
is 1234)
d. level 2 – Selects password to enter level 2 mode. (Default
is 1234)
(1 yes) button to accept selection (see Figure 163).
5. Press the
The computer displays FRYER SETUP on the left and 1234 on the right or the current
password.