Configuring Communication Connections
4.6.2

Specifying TCP Addresses

Address Parameters and Connection Types
With TCP, the communication partners are addressed by the local and remote
endpoints as follows:
S Local addresses:
Local IP address and local port
S Remote addresses:
Remote IP address and remote port
Ethernet station A
Figure 4-18
Sending and Receiving on One TCP Connection
Depending on the required connection type, the remote address parameters are
either specified or left open during configuration.
S Specified TCP connection
You specified a destination station when you created the connection.
S Unspecified TCP connection
You entered "unspecified" for the connection partner when you created the
connection.
122
remote
port
TCP
connection
local
port
MAC
address A
Ethernet station B
local
port
remote
port
IP address
B
SIMATIC NET NCM S7 for Industrial Ethernet