J1 and J2 (left) are Robnet2 connectors. J3 and J4 are SimNet
connectors.
AP27 connection
If a Simrad AP27 is part of the system, use the Robnet2
connector in a free receptacle (see Figure 3-9). Alternatively cut
the connector from the cable and connect the wires in parallel
with the cable shown on Figure 3-11 using the same colour code.
The AP27 cable contains an air-breathing tube. Check that the
Note !
tube is open after you have cut the cable.
3.13 RC36 Rate Compass installation
The heading sensor is the most important part of the autopilot
system and great care should be taken when deciding the
20221586B
AP26
CONTROL UNIT
REAR VIEW
Figure 3-11 Control unit connection
Figure 3-12
RC36 mounting
AUTOPILOT COMPUTER
MAIN P CB
Installation
TB15
Bn
Wh
Pnk Gry Yel
ROBNET