Specification And Product Numbers; General Specification Of Ex500 Series - SMC Networks EX500 Technical Instruction Manual

Hide thumbs Also See for EX500:
Table of Contents

Advertisement

EX500 Serial System

3. Specification and Product numbers

3 -1. General specification of EX500 series

Item
Enclosure
Standard
Withstand voltage
Insulation resistance
Momentary power failure
Ambient temperature
Ambient humidity
Preservation temperature
Vibration proof
Shock resistance
Applicable altitude
・ ・ ・ ・ EMC Directive ( 89 / 336 / EEC )
EN50081-2 / 1993, EN55011 / 1998 +A1 : 1999, EN50082-2 / 1995, EN61000-6-2 / 1999
Electromagnetic Emission
Item
Radiated Electric Field
Strength
Electromagnetic Susceptibility ( Immunity )
Item
ESD
RS :
Radiated Susceptibility
( amplitude modulated)
RS :
Radiated Susceptibility
( pulse modulated )
CS :
Conductive
Susceptibility
( amplitude modulated)
EFT / Burst,
DC power lines
EFT / Burst,
control lines
Surge,
interface lines
IP65
UL,CSA,CE
1500V AC 1min. ( between PE - external terminal package )
2MΩor more
( 500VDC meg. between PE - external terminal package )
1m sec. or less
+5℃ to +45℃
35% to 85%RH ( without condensation )
- 25℃ to 70℃
10Hz to 57Hz 0.35mm ( constant amplitude )
57Hz to 150Hz 5G ( constant speed )
2 hours per each direction of ±X,Y and Z
Peak value : 15G
3 times per each direction of ±X,Y and Z
Less than 1000m above sea
Test Procedure
EN55011 : 1998 +A1
: 1999
Test Procedure
EN61000-4-2 : 1995 /
A1 : 1998
EN61000-4-3 : 1996 /
A1 : 1998
ENV50204 : 1995
EN61000-4-6 : 1996
EN61000-4-4 : 1995
EN61000-4-4 : 1995
EN61000-4-5 : 1995
Specification
Specification
30MHz to 230MHz, 230MHz to 1GHz
( Distance : 10m )
Specification
±4kV contact
±8kV air discharge
80MHz to 1000MHz
10V / m ( 1kHz AM 80% )
900±5MHz
10V / m
( 200Hz Pulse Mod. Duty 50% )
0.15MHz to 80 MHz
10V ( 1kHz AM 80% )
±2kV
( 5 / 50ns, 5kHz )
±2kV
( 5 / 50ns, 5kHz )
±1kV ( Common )
- 7 -
EX## - OME0008
Criterion
Group 1
Class A
Criterion
B
A
A
A
B
B
B

Advertisement

Table of Contents
loading