Input Unit Manifold; Input Manifold; Input Unit - SMC Networks EX500 Technical Instruction Manual

Hide thumbs Also See for EX500:
Table of Contents

Advertisement

EX500 Serial System

3 -3. Input Unit Manifold

The Input Unit Manifold can have various combinations depending on the number of stations and type of
the sensor connector.
When placing an order, the input manifold part number and the input block part number are entered together.
But only one sensor type has to be specified per manifold ( either NPN or PNP ).
M8 Input Block

3 -3 -1. Input Manifold

The Input Manifold includes Input Unit ( EX500 - IB1 ( -X1 ) ), End Block and DIN rail.
How to Order
E E X 5 0 0 - I B 1
Input Unit Specification
Connector type
E M8 connector
T M12 connector
M M8, M12 mixed

3 -3 -2. Input Unit

How to Order
E X 5 0 0 - I B 1
Input Unit specification
Item
Connecting block
Number of connecting block
Power supply for block
Current supply for block
Current consumption
Short circuit protection
Communication connector
Weight
M12 Input Block
E
8
-
GW Unit compatible
DeviceNet
Nil
PROFIBUS-DP
-X1
Remote I/O ( RIO )
Stations
1
1 station
:
:
8
8 stations
GW Unit compatible
DeviceNet
Nil
PROFIBUS-DP
-X1
Remote I/O ( RIO )
Current source type Input Block ( PNP )
Current sink type input Block ( NPN )
8 blocks Max.
24V DC
0.65A Max.
100mA or less ( in case of rated voltage )
1A Typ. for each unit ( supply power cut )
Cut the power for power source once and then supply it again for return.
M12 connector ( 8 pin, plug )
Pin NO.
1. RD + 2. RD -
3. N. C. 4. N. C.
5. N. C. 6. N. C.
7. 24V DC ( for power source )
8. 0V DC ( for power source )
100g ( Input Unit + End Block )
- 11 -
M8 and M12 mixed
Input Manifold
Input Unit
Specification
or
EX## - OME0008
2
1
8
3
7
6
4
5
For Input Unit

Advertisement

Table of Contents
loading

Table of Contents