Download Print this page
Beyerdynamic RS 232 serial port Interface Protocol

Beyerdynamic RS 232 serial port Interface Protocol

Interface protocol rs 232 serial port

Advertisement

Quick Links

Interface protocol RS 232 serial port
Standard pin-out of any RS 232 com port (9 pin):
Sub- D
function
pin #
1
2
3
4
5
6
7
8
9
Parameters:
9600 Baud
8 Data bit
NO Parity
1 Stop bit
RTS means ready to send, normally active (+V);
CTS is waiting for the Clear-to-send signal from the control device (PC), if no CTS is sent, Pin 7
and 8 must be shortened inside the connector.
Software protocol:
Data exchange in true ASCII-Code. After any command a Carriage Return (0x0D) will be sent.
The Request-to-talk list is handled internally by the MCS 50 unit.
Please use a straight, standard RS 232 cable.
Page 1 of 3
For MCS 50 and MCS 50/64
Current version from 28.8.2003
Data Flow
MCS <-> control
-
TxD
RxD
-
GND
-
CTS
RTS
-
unit
-
->
<-
-
-
-
<-
->
-
06.12.2005

Advertisement

loading

Summary of Contents for Beyerdynamic RS 232 serial port

  • Page 1 Interface protocol RS 232 serial port For MCS 50 and MCS 50/64 Current version from 28.8.2003 Standard pin-out of any RS 232 com port (9 pin): Sub- D function Data Flow pin # MCS <-> control unit -> <- <- ->...
  • Page 2 List of Instructions: Command Data Flow Function MCS <-> PC or control panel ‘PXXX’,CR <- post status changing, 3 different ways: a) post not speaking will lead to post speaking b) post on Request-to-talk list will lead to post speaking (list must be updated too) c) post speaking will lead to post not speaking XXX = Post number (000 –...
  • Page 3 Output level is lowered gradually MCS 50 sends echo‘P070’,CR ‘R070’,CR <- stop lowering output level MCS 50 sends echo‘R070’,CR ‘P071’,CR <- Volume + (increase) Output level is increased gradually MCS 50 sends echo ‘P071’,CR ‘R071’,CR <- stop increasing output level MCS 50 sends echo ‘R071’,CR ‘P072’,CR <-...

This manual is also suitable for:

Mcs 50Mcs 50/64