10. Power Connection — connect AC power cords to all Encore and peripheral
11. System ID — Using the Unit ID Selector, set the ID of Processor #1 to 1,
12. Power On — Refer to Chapter 6 of the Encore Presentation System User's
Encore VPx Installation Guide • 08-0311105-00 Rev 00
Connect the computer's "head 2" to processor 2, input 3A
Connect the computer's "head 3" to processor 3, input 3A
Note
Input 3A resides on the lowest priority M/E in a 3 M/E system.
To connect a second background, use input 3B.
c.
The DSK source may originate from a computer with a multi-head
graphics card, but it is not a requirement.
To use a multi-head graphics card for the DSK, connect it to the same
input on each VPx — to the highest priority M/E (M/E 1).
To connect an unscaled DSK source in a triple processor system
(each processor with three M/Es):
Connect the computer's "head 1" to processor 1, input 1A
Connect the computer's "head 2" to processor 2, input 1A
Connect the computer's "head 3" to processor 3, input 1A
Note
Input 1A resides on the highest priority M/E in a 3 M/E Encore
system. If you wish to connect a backup DSK, use input 1B.
Output Connections —
a.
For each VPx, connect the analog or digital Preview Output to the input
of the associated Preview Monitor.
b.
For each VPx, connect the analog or digital Program 2 Output to the
input of the associated Program Monitor.
c.
For each VPx, connect the analog or digital Program 1 Output to the
input of the associated projector.
d.
Connect the Program Out HD/SDI connector to an SDI or HDTV monitor
as required, or to the proper video distribution equipment.
Note
This output only works if the selected output resolution is a
valid SDI or HD/SDI format.
Link Connections — in a widescreen application, the Program Link and Source
Link connections are used to connect processors together, and bridge inputs and
outputs for the proper "overlap" between projectors. In Chapter 3 of the Encore
Presentation System User's Guide, refer to the "Program and Source Link
Connections" section for details.
equipment, and then to AC outlets.
Processor #2 to 2, and Processor #3 to 3. Each unit must have a unique ID.
Remember that you can redefine IDs using numbers 17 - 32 from the
Miscellaneous Menu.
Guide for all power on instructions.
båÅçêÉ=smñ=fåëí~ää~íáçå=dìáÇÉ
Installation
19