6
O
PERATIONAL MALFUNCTIONS
6.2 E
RROR MESSAGES
Message
Description
E__7
Photoelectric sensor in the loop
space does not detect the loop for-
mation; label stop sensor does not
detect the labels and problem with
the rewind unit.
E_10
Error in the applicator section (op-
tional)
E_11
Many products are not labelled. The
number of unlabelled products is
greater than the amount set in the
MLAB function.
E_12
Invalid setting value
Factory settings are activated, see
appendix.
E_13
Label roll is completely consumed.
Labels are no longer detected at the
label stop sensor.
E_14
Too many products between product
sensor and dispensing edge.
Possible causes and remedies
Refer to E__1, E__2, and E__4.
Only when an applicator is used:
Inspection of the compressed air connection and the
neutral position sensor by servicing technicians is re-
quired; see the operating manual of the applicator.
The distance between the products on the conveyor
belt is insufficient:
➔
Increase the product distance.
➔
For circumferential labelling: Increase the rotation-
al speed.
The product triggers several start signals, caused by
reflections, for example:
➔
Adjust the product length (PRDL function).
When using a printer, the printing time is too long:
➔
If possible, decrease the printer dwell time (PDWT
function).
➔
Start printing process before label stop (PDT func-
tion).
Several labels are missing from the label ribbon:
➔
Replace label roll
or
➔
Increase value for MLAB, if possible.
A serious memory error has occurred:
– The control system needs to be reconfigured by a
servicing technician or Avery Dennison's custom-
er service; refer to the Service Guide.
➔
Replace label roll.
Product sensor located too far from dispensing edge:
– A maximum of 7 products can be located between
the product sensor and the dispensing edge.
➔
Change the position of the product sensor.
➔
Subsequently correct the POS setting.
The product triggers several start signals, caused by
reflections, for example:
➔
Adjust the product length (PRDL function).
80