8000 Touchscreen Programmable Thermostat
Manual Override of Fan Schedule (Table 8)
Auto—fan is automatically following the Fan schedule
(choices are Auto, On or Circulate).
On—overrides Fan schedule. Fan is continuously On.
Circ—overrides Fan schedule. Fan circulates randomly for
approximately 35% of time until the Auto position is selected.
Table 8. Manual Override of Fan Schedule Operation.
Fan
Schedule
Fan
Override
Setting
Setting
Action
Auto
On
Fan
Auto
Circ
None
Auto
Circ
Fan
On
a
Auto
On
Circ
None
On
Circ
Fan
Circ
a
Auto
Circ
On
Fan
a
Auto Override resumes the Fan Program in each schedule
period (Wake, Leave, Return and Sleep)
68-0280—01
Screen
Message
Call
Under
for
Energize
Fan
Terminal
Setting
G
On
None
Circ
G
Circ
—
—
—
None
Circ
G
Circ
—
—
—
G
On
Operate VisionPRO™ 8000 Touchscreen
Set Time
1. Press Clock.
2. Use arrows to set current time.
TUE
DONE
3. Press Done key.
IMPORTANT
The current day of the week should already be set
correctly. If not, see Installer Setup to set the day.
Set Temperature Overrides
The thermostat has three temperature override options: Hold
Temperature Until, Permanent Hold and Vacation Hold.
HOLD TEMPERATURE UNTIL (TEMPORARY HOLD)
Holds temperature temporarily until the next scheduled period
time or until the time the user sets.
1. Press Up or Down arrow next to the temperature you
want to adjust. "Hold Temperature Until" time appears
on the screen. The Hold Temperature Until time defaults
to the start time of the next scheduled period.
NOTE: The Time Up and Down arrows are shown for
approximately seven seconds. Pressing on the
screen time (where the Hold Temperature Until time
is shown) allows the arrows to reappear.
26
AM
CANCEL
M19958