Honeywell VisionPRO 8000 Product Data page 19

8000 series touchscreen programmable thermostat
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

Installer Setup
Number
Installer Setup Name
0650
Extended Fan OnTime
Heat
0660
Extended Fan On Time
Cool
0670
Keypad Lockout
0680
Temperature Control in
Heat
0690
Temperature Control in
Cool
0700
Temperature Display
Offset
0710
Reset Thermostat
VisionPRO
Table 3. Installer Setup Menu. (Continued)
Settings
0—no extended fan operation after call for heat ends
90— fan operation is extended 90 seconds after call for
heat ends.
0—no extended fan operation after call for cool ends
90—fan operation is extended 90 seconds after call for
cool ends.
0—unlocked keypad
1—partially locked keypad
2—fully locked keypad
1—less aggressive temperature control (could cause
temperature undershoot)
2—Standard temperature control in heating (factory
setting)
3—more aggressive temperature control (could cause
temperature overshoot)
1—less aggressive temperature control (could cause
temperature undershoot)
2—Standard temperature control in cooling
(factory setting)
3—more aggressive temperature control (could cause
temperature overshoot)
°
°
-3 —
F (-1.5
C)
-2 —°F (-1°C)
-1 —°F (-.5°C)
0 —°F (0. °C) — (no difference in displayed temperature
and actual room temperature )
1 —°F (.5°C)
2 —°F (1°C
3 —°F (1.5°C)
0—no thermostat reset.
1—resets all Installer Setup Options to default values and
resets schedule to default setting.
19
TM
8000 Touchscreen Programmable Thermostat
Not shown if fan operation
is set to fossil fuel or in
Cool Only Systems
Not shown in Heat Only
Systems.
Unlocked—all functions
are available.
Partially locked—only
temperature up and down
keys and ability to enter
and modify Installer Setup
mode are available.
Fully locked—only ability
to enter and modify
Installer Setup mode are
available.
Applies to recovery ramp
and use of auxiliary heat
during recovery.
Choose 1 if getting
temperature overshoot.
Choose 3 if getting
temperature undershoot.
Applies to recovery ramp.
Choose 1 if getting
temperature overshoot.
Choose 3 if getting
temperature undershoot.
Only calendar settings
and time are retained.
Notes