2.1.4 Switch Bottom Panel
The bottom panel of the 5/8-Port 10/100BaseTX Industrial Switch consist one terminal block connector
within two DC power inputs and one DC IN power jack for extra AC/DC power adapter. Figure 2-3 shows
the bottom panel of the switch.
Figure 2-3 ISW-500/800 Bottom Panel.

2.1.5 Wiring the Power Inputs

Please follow below steps to insert the power wire.
V -
V +
V -
V +
1. Insert the positive and negative wires into the V+ and V- connector on the terminal block connector.
2. To tighten the wire-clamp screws for preventing the DC wires to loose.
Power Notice:
The wire range of terminal block is from 12~ 24 AWG.