From the WEB interface it is possible to, among other things:
● Set port mode.
● Enable/disable flow control.
● Configure simple port-based VLAN.
● Configure aggregation groups
● Configure QoS.
● Read and clear statistics counters.
● Upgrade software
All operations are password protected. The password must be entered at login. The
password is the same as is being used in the command line interface.
As stated in chapter 3 the IP mode is disabled in the factory default configuration.
To be able to use the WEB interface, the IP must be enabled and configured via the
command line interface. The IP address, mask and gateway must be set according to your
environment. Example on enabling the WEB interface via the command line interface:
>ip setup 192.168.0.100 255.255.252.0 192.168.0.254 1
>ip mode enable
4.1 Starting the Web Interface
Follow these steps to bring up the switch Web interface:
1. Enter the IP address of the switch in the Web browser address field.
2. Enter password. The password is the same as the CLI interface. Click on the
Apply button.
3. Make your selection by clicking on the item in menu frame.
Chapter 4
WEB Interface
25