Changing The Wan Ip Address; Connecting The Smartnode To The Network - Patton electronics SmartNode 4960 Series Quick Start Manual

Multi-port t1/e1/pri voip enterprise session border router
Hide thumbs Also See for SmartNode 4960 Series:
Table of Contents

Advertisement

3.2 Login
To access the SmartNode, start the Telnet application on your PC. Type the default IP address into the
1.
address field: 192.168.1.1. Accessing your SmartNode via a Telnet session displays the login screen.
Type the factory default login: administrator and leave the password empty. Press the Enter key after the
password prompt.
login:administrator
password:<Enter>
192.168.1.1>
After you log in, your SmartNode will be running in operator execution mode (indicated by > character in
2.
the command line prompt). To enter configuration mode, use the commands enable and configure.
192.168.1.1>enable
192.168.1.1#configure
192.168.1.1(cfg)#

3.3 Changing the WAN IP address

To modify IP configuration settings, you must enter context IP mode. Enter the following command:
1.
192.168.1.1(cfg)#context ip router
192.168.1.1(ctx-ip)[router]#
2.
Now you can set your IP address and network mask for the interface ETH 0/0(WAN). In this example a
network 172.16.1.0/24 is assumed. The IP address in example is set to 172.16.1.99. (You should set it
to the IP address that the network provider has given you.)
The examples in this guide use a private IP network with the network address 172.16.1.0/24.
Note
192.168.1.1(ctx-ip)[router]#interface WAN
192.168.1.1(if-ip)[WAN]#ipaddress 172.16.1.99 255.255.255.0
2002-10-29T00:09:40 : LOGINFO
2002-10-29T00:09:40 : LOGINFO
172.16.1.99(if-ip)[WAN]#
Copy this modified configuration to your new start-up configuration. This will store your changes in non-
3.
volatile memory. On the next start-up the system will initialize itself using the modified configuration.
172.16.1.99 (if-ip)[WAN]#copy running-config startup-config
172.16.1.99 (if-ip)[WAN]#
The SmartNode can now be connected to your network.

4.0 Connecting the SmartNode to the network

CAUTION
SmartNode 4960 Series Quick Start Guide
The interconnecting cables shall be acceptable for external use and shall be rated for
the proper application with respect to voltage, current, anticipated temperature, flam-
mability, and mechanical serviceability.
: Link down on interface WAN.
: Link up on interface WAN.