Connecting The Smartnode To The Network; Changing The Wan Ip Address - Patton electronics 4950-NCE Quick Start Manual

Multi-port t1/e1/pri voip enterprise gateway router
Hide thumbs Also See for 4950-NCE:
Table of Contents

Advertisement

3.2 Login
To access the SmartNode, start the Telnet application on your PC. Type the default IP address into the
1.
address field: 192.168.1.1. Accessing your SmartNode via a Telnet session displays the login screen.
Type the factory default login: administrator and leave the password empty. Press the Enter key after the
password prompt.
login:administrator
password:<Enter>
192.168.1.1>
After you log in, your SmartNode will be running in operator execution mode (indicated by > character in
2.
the command line prompt). To enter configuration mode, use the commands enable and configure.
192.168.1.1>enable
192.168.1.1#configure
192.168.1.1(cfg)#

3.3 Changing the WAN IP address

To modify IP configuration settings, you must enter context IP mode. Enter the following command:
1.
192.168.1.1(cfg)#context ip router
192.168.1.1(ctx-ip)[router]#
2.
Now you can set your IP address and network mask for the interface ETH 0/0(WAN). In this example a
network 172.16.1.0/24 is assumed. The IP address in example is set to 172.16.1.99. (You should set it
to the IP address that the network provider has given you.)
The examples in this guide use a private IP network with the network address 172.16.1.0/24.
Note
192.168.1.1(ctx-ip)[router]#interface WAN
192.168.1.1(if-ip)[WAN]#ipaddress 172.16.1.99 255.255.255.0
2002-10-29T00:09:40 : LOGINFO
2002-10-29T00:09:40 : LOGINFO
172.16.1.99(if-ip)[WAN]#
Copy this modified configuration to your new start-up configuration. This will store your changes in non-
3.
volatile memory. On the next start-up the system will initialize itself using the modified configuration.
172.16.1.99 (if-ip)[WAN]#copy running-config startup-config
172.16.1.99 (if-ip)[WAN]#
The SmartNode can now be connected to your network.

4.0 Connecting the SmartNode to the network

CAUTION
SmartNode 4950-NCE Series Quick Start Guide
The interconnecting cables shall be acceptable for external use and shall be rated for
the proper application with respect to voltage, current, anticipated temperature, flam-
mability, and mechanical serviceability.
: Link down on interface WAN.
: Link up on interface WAN.
5