Patton electronics 2120 User Manual page 22

Rs-232 single port terminal server
Table of Contents

Advertisement

1.
Verify that the four internal DIP switches are set to the OFF position
(factory default).
2.
Using ribbon cable or other similar cable, connect the serial RS-232
port of a VT-100 ASCII terminal or similar DTE with terminal emula-
tion software to the RS-232 port of the Model 2120.
3.
Power up the emulation device and configure its RS-232 port as
follows:
– 9600 Baud
– 8 data bits, 1 stop bit, no parity
– ANSI, VT100 emulation
4.
Power up the Model 2120.
5.
After the Model 2120 is powered on, the ASCII terminal or emulation
device should display the following message:
Model 2
120 Terminal Server
Software Version ?.?.? (will display current version)
TS>
Note
If you are unable to connect with the Model 2120 and you have
rechecked your terminal emulation settings, it is recommended
that a configuration reset (to factory defaults) be performed on
the Model 2120 by setting internal dip switch #1 to the ON posi-
tion and power cycling the Model 2120. Once powered on, set
switch #1 back to the OFF position. If still unable to establish a
connection, please contact Patton Electronics Technical Support
at (301) 975-1007.
6.
Press the <Enter> key to see the main help menu screen.
*** Help Menu ***
activateimage
boot
configure
eiaconclose
ftp
ping
rawtcp
show
telnet
TS>
- Activate Image Acquired With FTP Get
- Boot System
- Configure Parameters
- EIA232 Connection Close
- FTP To Remote Device
- Ping Remote Device
- Raw-TCP To Remote Device
- Show Parameters and Statistics
- Telnet To Remote Device
22