c. 4+1 Express Format
This DTMF format consists of a four digit account code, two digit message type, and a single digit event code.
d. 4+2 Express Format
This DTMF format consists of a four digit account code, two digit message type, and a two digit event code.
O
p
e
r
a
t
i
o
n
O
p
e
r
a
t
i
o
n
A. Standard Operation
1. "HELP" / "CALL" Button
When the "HELP" / "CALL" button is pressed, the 1600A series phone goes off-hook and dials a pre-programmed
telephone number. The Call Connected LED momentarily flashes during tone or pulse dialing. In the event the line
is busy or there is a ring-no-answer, the unit can be programmed to call additional phone numbers. The phone then
cycles through up to 5 pre-programmed emergency numbers until the call is answered. When the call is answered,
the digital voice announcer will automatically play to identify the location of the emergency call. The phones are fac-
tory programmed to play the announcement once, and the automatically light the "Call Connected" LED to show
that handsfree communication to emergency personnel is established. The
grammed), and play the announcement again. The distant party will know the location of the emergency call by
either the voice announcement or by decoding the touch tone I.D. number. Once the "Call Connected" LED is on,
the # key can be used to force the phone to hang up.
2. "INFO" Button (E-1600A-TP2-EWP only)
When the "INFO" button is pressed (E-1600A-TP2-EWP only), the phone goes off-hook and dials the first "INFO"
phone number programmed. If a busy signal is detected or the call goes unanswered, the phone will cycle through
all three "INFO" phone numbers until the call is answered. When answered, handsfree communication is estab-
lished. Note: The voice announcement is for Emergency/Help calls only and will not play on a call initiated from
the "INFO" button.
Account Code
Message Type
Enter 4+1 Express ID Settings Here:
XXXX 27 XX #20
Account Code
Message Type
Enter 4+2 Express ID Settings Here:
XXXX 17 X #20
Memory Location
Event Code
Memory Location
Event Code
17
#20
27
#20
Q
key will send the I.D. number (if pro-