APPLICATION
APPLICATION
T
T
E
L
E
E
L
E
E-1600-45A
Once the receiver has issued the proper acknowledgement tone, the "CALL CONNECTED" indicator on
the front of the emergency phone will light, and the 1600A phone will then switch to two-way voice or call
a voice line.
The 1600A Series emergency phone may NOT be compatible with certain Central Station
!
Monitoring equipment. If you experience problems, contact Product Support at 715-386-8666.
P
r
o
g
r
a
m
m
P
r
o
g
r
a
m
m
The standard 1600A emergency phone is factory programmed to communicate using the "Ademco Contact I.D.", "Ademco
High Speed", "DTMF 4+1 Express", or the "DTMF 4+2 Express" formats. All formats use the programming memory loca-
tion #20 to store the account code and alarm details.
A. Programming Features
1. Accessing the Programming Mode
Before programming, you must access the programming mode (see 1600A Technical Practice, section A).
2. Enabling/Disabling Central Station Mode
The 1600A Series emergency phone can be placed in the "Central Station Mode" by entering a central station phone
number in position #05 while programming. To cancel the "Central Station Mode," clear position #05 by entering
#05 (see 1600A Technical Practice, section F).
3. Ring Delay
When the 1600A Series emergency phone is in the "Central Station Mode", it is best to have the ring delay set to
a minimum of three. Some receivers send a long tone after answering the line that sounds like a ring back, and if
the 1600A is set to a ring delay of two, the phone will disconnect (see 1600A Technical Practice, section F).
4. Speed Dial Numbers
The 1600A Series phone can be programmed to dial a central station receiver only, or dial up to 5 voice numbers
first, and if no answer, then dial the central station receiver. When calling the first numbers (memory positions #00-
#04, see 1600A Technical Practice, section C), the phone stays in "two-way talk mode" allowing two-way conver-
sation. When calling the Central Station number (memory position #05), the phone is in a "listen only mode" in order
to interpret the hand shake signal of the receiver.
A second central station number position has been provided in location #06 that is used when the central station
receiver does not have a talk over mode. If a number is placed in position #05 and position #06 is cleared, the
operation is as follows: the E-1600A will call the central station monitor receiver first. After the receiver sends a
kiss-off, the E-1600A lights the "Call Connected" LED and goes into two-way talk mode.
S
S
C
O
M
O
L
U
T
I
O
N
S
C
O
M
O
L
U
T
I
O
N
S
Using the 1600A Series Phones with
Central Station Equipment
K-1600-EHFA
E-1600A
i
n
g
i
n
g
N
N
2
1
C
2
1
C
F
O
R
T
H
E
S
T
F
O
R
T
H
E
S
T
Note: This document must be used in combina-
tion with the 1600A Series Technical Practice (Fax
Back Document 215).
E-1600-02A
E-1600-03A
E-1600-20A
1600A Series
1600A Series
Central Station
o
t
e
o
t
e
Monitoring
August 28, 2001
E
N
T
U
R
Y
E
N
T
U
R
Y
The 1600A Series emergency telephones
have the capability to communicate directly
with several central station receiver formats.
In this mode, the emergency
phone
will
vital information to compatible
equipment at central alarm moni-
toring stations.
automatically relay

Advertisement

loading

Summary of Contents for Viking E-1600-02A

  • Page 1 E-1600A will call the central station monitor receiver first. After the receiver sends a kiss-off, the E-1600A lights the “Call Connected” LED and goes into two-way talk mode. Central Station Equipment E-1600-02A E-1600-03A E-1600A 1600A Series...
  • Page 2 Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information.

This manual is also suitable for:

E-1600-03aE-1600-20aE-1600-45aE-1600aK-1600-ehfa