TECHNICAL
TECHNICAL
E-1600A-TP-EWP
voice communication is possible during power failures. All phone numbers, location numbers, voice announcement
and programming parameters are stored in non-volatile memory. No batteries are required.
The E-1600A-TP-EWP and E-1600A-TP2-EWP are equipped for outdoor or harsh environments with Enhanced
Weather Protection, which features: potted circuit boards, sealed trim pots and dip switches, rubber gaskets and
boots, gel-filled butt connectors, and extended operating temperature: -15°F to 130°F, tested to -35°F.
P
P
• Enhanced Weather Protection (EWP)
• Meets ADA requirements for Emergency Phones:
- Can automatically light the "Call Connected" LED for the
hearing impaired
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired
• Non-volatile digital voice announcer with 16 seconds of voice
memory
• Provides contact or switched 12V DC for controlling a strobe light
• Advanced call progress detection
• Handsfree operation
• Phone line powered emergency phone (LDB-3 requires power)
• Non-volatile memory (no batteries required)
• Touch Tone or pulse dialing
• Dials up to 5 emergency numbers
• E-1600A-TP2-EWP can also dial up to 3 non-emergency "Info"
numbers
• Cycles through backup emergency and non-emergency numbers
on busy or no-answer
• Hangs up on CPC, silence, busy signal, dial tone, time-out or
touch tone command
• Programmable to auto-answer on incoming calls
• Remotely programmable
• Extended temperature range (-15°F to 130°F)
• Central Station Monitoring capability (dials 2 numbers)
• Separate central station voice speed dial number
• Optional PB-100 Polling System available (see page 10)
• High visibility, vandal and weather resistant
E-1600A-TP2-EWP
h
o
n
e
.
.
.
7
1
5
.
3
8
6
.
8
h
o
n
e
.
.
.
7
1
5
.
3
8
6
.
8
P
r
a
c
t
P
r
a
c
For use with Talk-A-Phone tower, pedestal, surface, wall
and flush mount enclosures. Code Blue towers require
redrilling and tapping.
The E-1600A-TP-EWP or E-1600A-TP2-EWP will call up
to 5 programmable emergency numbers, as well as 2 cen-
tral station numbers and send a digital announcement to
identify the location of the emergency call. The included
LDB-3 control module will supply a contact or switched
12V DC to activate a strobe light. In addition, the E-1600A-
TP2-EWP features a second "Info" button that will dial up
to 3 non-emergency numbers.
Though the strobe requires external power to operate,
8
6
1
8
6
1
• Campus Security Sites
• Area of Refuge sites
• Parking Ramps/Lots
• Automated Tellers (ATM)
• Entryways
• Roadside Emergency Sites
• Stairwells in Public Buildings
Some phone systems do not conform to analog telecom standards and might
not be compatible with the 1600A Series emergency phones. For a detailed
description of the telephone line specifications required for any of the 1600A
Series phones, retrieve Fax Back Document 869.
Phone Power:
voltage, with a minimum loop current of 20mA. Loop current may be
boosted on low current lines with a Viking Model TBB-1 talk battery boost-
er (Fax Back # 630).
LDB-3 Control Module: 120V AC/12V DC 500mA, UL listed
adapter provided
Dimensions: 241mm x 299mm x 51mm (9.5" x11.75" x2")
Shipping Weight:
Mounting: Flush mount to Talk-A-Phone ETP towers, wall
mounts, boxes and pedestals
Environmental: -26°C to 54°C (-15°F to 130°F) with up to 100%
condensing humidity
Material: .125" (11 gauge) brushed stainless steel
Connections: Color-coded wires with gel-filled butt connectors
E-1600A-TP-EWP
E-1600A-TP-EWP
E-1600A-TP2-EWP
E-1600A-TP2-EWP
i
c
e
t
i
c
e
February 29, 2008
Telephone line powered. Minimum 24V DC talk battery
2.9 kg (6.4 lbs)