Hide thumbs Also See for E-1600A-GT-EWP:

Advertisement

Quick Links

TECHNICAL
TECHNICAL
S
S
Direct Physical Replacement for: Talk-A-Phone models ETP-400V and
ETP-400DV, GAI-Tronics models 397-001, 397-002, 397-003 and 397-004
For use with Talk-A-Phone or GAI-Tronics tower, stan-
chion, pedestal, surface, wall and flush mount enclo-
sures. Code Blue towers require redrilling and tapping.
The
E-1600A-GT-EWP will call up to 5 programmable emer-
gency numbers, as well as 2 central station numbers
and send a digital announcement to identify the location
of the emergency call. The included BLK-4 control
module will supply a contact or switched 12V DC to acti-
vate a strobe light. In addition, the E-1600A-TP2-EWP
features a second "Info" button that will dial up to 3 non-
emergency numbers.
Though the strobe requires external power to operate,
voice communication is possible during power failures.
All phone numbers, location numbers, voice announce-
ment and programming parameters are stored in
non-volatile memory. No batteries are required.
The
E-1600A-TP-EWP,
E-1600A-GT-EWP are equipped with Enhanced
F
e
a
t
u
r
e
s
F
e
a
t
u
r
e
s
• New Automatic Noise Canceling (ANC) feature for proper opera-
tion in noisy environments
• Enhanced Weather Protection (EWP), EWP products are designed to
meet IP66 Ingress Protection Rating, see DOD 859
• Meets ADA requirements for Emergency Phones:
- Automatically lights the "Call Connected" LED
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired
• Non-volatile digital voice announcer with 16 seconds of voice memory
• Provides contact or switched 12V DC for controlling a strobe light
• Advanced call progress detection
• Handsfree operation
• Phone line powered emergency phone (BLK-4 requires power)
• Non-volatile memory (no batteries required)
• Marine grade 316 stainless steel prevents corrosion
• Dials up to 5 emergency numbers
• E-1600A-TP2-EWP can also dial up to 3 non-emergency "Info" num-
bers
• Cycles through backup phone numbers on busy or no-answer
• Hangs up on CPC, silence, busy signal, dial tone, time-out or touch
tone command
• Programmable to auto-answer on incoming calls
• Remotely programmable
• Extended temperature range (-15°F to 130°F)
• Central Station Monitoring capability (dials two numbers)
• Separate central station voice speed dial number
• Optional PB-100 Polling System available
• High visibility, vandal and weather resistant
C
C
E
C
U
R
I
T
Y
A
N
D
O
E
C
U
R
I
T
Y
A
N
D
O
E-1600A-TP-EWP,
E-1600A-TP2-EWP
E-1600A-TP2-EWP
P
r
a
c
P
r
a
c
S
S
M
M
U
N
I
C
A
T
I
O
N
O
M
M
U
N
I
C
A
T
I
O
N
O
or
E-1600A-TP-EWP
Weather Protection (EWP) for outdoor installations where
the unit is exposed to precipitation or condensation. EWP
products feature foam rubber gaskets and boots, sealed
connections, gel-filled butt connectors, as well as ure-
thane or thermal plastic potted circuit boards with inter-
and
nally sealed, field-adjustable trim pots and DIP switches
for easy on-site programming. For more information, see
DOD 859.
A
p
p
l
A
p
p
• Replacing weather damaged Talk-A-Phone or GAI-Tronics
panel phones
• Campus Security Sites
• Area of Refuge sites
• Parking Ramps/Lots
• Automated Tellers (ATM)
• Entryways
• Roadside Emergency Sites
• Stairwells in Public Buildings
CAUTION - When installing on an analog extension of a phone system:
Some phone systems do not conform to analog telecom standards and might
not be compatible with the 1600A Series emergency phones. For a detailed
description of the telephone line specifications required for any of the 1600A
Series phones, see DOD 869.
S
p
e
c
S
p
e
c
Phone Power: Telephone line powered. Minimum 24V DC talk battery
voltage, with a minimum loop current of 20mA. Loop current may be
boosted on low current lines with a Viking Model TBB-1B talk battery
booster (DOD 632).
BLK-4 Control Module: 120V AC/12V DC 500mA, UL listed adapter pro-
vided
Dimensions: See Installation
Shipping Weight: 6.4 lbs (2.9 kg)
Mounting: Flush mount to Talk-A-Phone ETP towers, wall mounts, boxes
and pedestals
Environmental: -15°F to 130°F (-26°C to 54°C) with up to 100% con-
densing humidity
Material: .105" (12 gauge) brushed Marine grade 316 stainless steel
Connections: Color-coded wires with gel-filled butt connectors
E-1600A-TP-EWP
E-1600A-TP-EWP
E-1600A-TP2-EWP
E-1600A-TP2-EWP
E-1600A-GT-EWP
E-1600A-GT-EWP
t
i
c
e
t
i
c
e
ADA Emergency Phone Replacements
for Talk-A-Phone and GAI-Tronics
L
U
T
I
O
N
S
L
U
T
I
O
N
S
E-1600A-TP2-EWP
Material: Brushed 316 Stainless Steel
i
c
a
t
i
o
n
s
l
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
May 29 , 2019
E-1600A-GT-EWP

Advertisement

Table of Contents
loading

Summary of Contents for Viking E-1600A-GT-EWP

  • Page 1 20mA. Loop current may be • Cycles through backup phone numbers on busy or no-answer boosted on low current lines with a Viking Model TBB-1B talk battery • Hangs up on CPC, silence, busy signal, dial tone, time-out or touch booster (DOD 632).
  • Page 2 TWO YEAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.
  • Page 3 5.125 available on model E-1600A-TP2-EWP) PUSH FOR HELP Marine grade 316 stainless steel faceplate and push button switch (sealed per IP67) VIKING © Grade 2 Braille Label 2.125 (6) 0.250 diameter counter sunk 82° x 0.410 0.75 diameter holes for flathead #10 x 24 tamper-proof screws (not included) 2.75...
  • Page 4: Dip Switches

    C. E-1600A-GT-EWP Panel Dimensions 10.00 8.000 1.200 EMERGENCY PHONE 4.800 "Call Connected" LED Push for "Help" Button 12.00 1.755 CALL 2.725 CONNECTED PUSH FOR Grade 2 Braille Label HELP 4.800 VIKING © (6) 0.250 diameter holes (clearance holes for #10-32...
  • Page 5 Step 5. When finished programming, move DIP switch 3 back to the ON position (see section J). Warning: Failure to do step 5 above will cause the 1600A Series to call Viking Technical Support instead of your programmed number. See Section I, Assisted Programming.
  • Page 6: Speed Dial Numbers

    B. Quick Programming Features Enter Digits - then - Enter Memory Location First emergency speed dial number ................. 0-20 digits then Second emergency speed dial number ..............0-20 digits then Third emergency speed dial number ............... 0-20 digits then Fourth emergency speed dial number ..............0-20 digits then Fifth emergency speed dial number .................
  • Page 7: Identification Number

    E. Identification Number (memory location #20) The Touch Tone I.D. number (up to 20 digits) is used by emergency personnel to identify the location of the caller and is given out when the receiving party presses a Touch Tone Q. The security office can display the number using a Touch Tone decoder.
  • Page 8 G. Voice Announcer/Miscellaneous Options (memory location #17) The 1600A series phones have a built-in non-volatile digital voice announcer that may be used to identify the location of the emergency phone call. The 16 seconds of digital record time is recorded remotely from a Touch Tone phone. Programming options are as follows: Dial: A + B + C + D + E + F + # + 1 + 7 Factory Default Setting: 0 + 0 + 1 + 2 + 1 + 0...
  • Page 9: Recording The Announcement

    CO line, or behind a "dial 9" PBX. The 1600A Series phone will first dial 9, and then listen for second dial tone; if detected it will continue to dial Viking’s assisted programming phone number. If a second dial tone is not detected, it then knows is not behind a PBX, so it will momentarily hang up and then directly dial Viking’s assisted programming phone number.
  • Page 10 K. Central Station Programming The standard 1600A emergency phone is capable of communicating using the “Ademco Contact I.D.”, “Ademco High Speed”, “DTMF 4+1 Express”, or the “DTMF 4+2 Express” formats. All formats use the programming memory location #20 to store the account code and alarm details. 1.
  • Page 11 2. Central Station Formats The following examples explain the receiver formats and how to properly program memory location #20. Each for- mat starts with a four digit account code. This is the code that is assigned by your central station for billing purpos- es.
  • Page 12: Standard Operation

    LED and goes into the “two-way talk mode” or hangs up and dials position #06 if programmed. Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information.

This manual is also suitable for:

E-1600a-tp2-ewpE-1600a-tp-ewp

Table of Contents