Models ETP-400V and ETP-400DV Panel Phones
E-1600A-TP-EWP
voice communication is possible during power failures. All phone numbers, location numbers, voice announcement
and programming parameters are stored in non-volatile memory. No batteries are required.
The E-1600A-TP-EWP and E-1600A-TP2-EWP are equipped with Enhanced Weather Protection (EWP) for outdoor
installations where the unit is exposed to precipitation or condensation. EWP products feature foam rubber gaskets
and boots, sealed connections, gel-filled butt connectors, as well as urethane or thermal plastic potted circuit boards
with internally sealed, field-adjustable trim pots and DIP switches for easy on-site programming. For more informa-
tion, see DOD# 859.
P
P
F
e
a
t
u
r
e
s
F
e
a
t
u
r
e
s
• Enhanced Weather Protection (EWP), EWP products are designed
to meet IP66 Ingress Protection Rating, see DOD# 859
• Meets ADA requirements for Emergency Phones:
- Can automatically light the "Call Connected" LED for the
hearing impaired
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired
• Non-volatile digital voice announcer with 16 seconds of voice
memory
• Provides contact or switched 12V DC for controlling a strobe light
• Advanced call progress detection
• Handsfree operation
• Phone line powered emergency phone (LDB-3 requires power)
• Non-volatile memory (no batteries required)
• Marine grade 316 stainless steel prevents corrosion
• Dials up to 5 emergency numbers
• E-1600A-TP2-EWP can also dial up to 3 non-emergency "Info"
numbers
• Cycles through backup emergency and non-emergency numbers
on busy or no-answer
• Hangs up on CPC, silence, busy signal, dial tone, time-out or
touch tone command
• Programmable to auto-answer on incoming calls
• Remotely programmable
• Extended temperature range (-15°F to 130°F)
• Central Station Monitoring capability (dials 2 numbers)
• Separate central station voice speed dial number
• Optional PB-100 Polling System available (see page 10)
• High visibility, vandal and weather resistant
C
C
E
C
U
R
I
T
Y
A
N
D
O
E
C
U
R
I
T
Y
A
N
D
O
Direct Physical Replacement for Talk-A-Phone
E-1600A-TP2-EWP
Material: Brushed 316 Stainless Steel
h
o
n
e
.
.
.
7
1
5
.
3
8
6
h
o
n
e
.
.
.
7
1
5
.
3
8
6
P
r
a
c
P
r
a
c
S
S
M
M
U
N
I
C
A
T
I
O
N
O
M
M
U
N
I
C
A
T
I
O
N
O
For use with Talk-A-Phone tower, pedestal, surface, wall
and flush mount enclosures. Code Blue towers require
redrilling and tapping.
The E-1600A-TP-EWP or E-1600A-TP2-EWP will call up
to 5 programmable emergency numbers, as well as 2 cen-
tral station numbers and send a digital announcement to
identify the location of the emergency call. The included
LDB-3 control module will supply a contact or switched
12V DC to activate a strobe light. In addition, the E-1600A-
TP2-EWP features a second "Info" button that will dial up
to 3 non-emergency numbers.
Though the strobe requires external power to operate,
A
p
p
A
p
p
.
8
8
6
1
.
8
8
6
1
• Campus Security Sites
• Area of Refuge sites
• Parking Ramps/Lots
• Automated Tellers (ATM)
• Entryways
• Roadside Emergency Sites
• Stairwells in Public Buildings
CAUTION - When installing on an analog extension of a phone system:
Some phone systems do not conform to analog telecom standards and might
not be compatible with the 1600A Series emergency phones. For a detailed
description of the telephone line specifications required for any of the 1600A
Series phones, see DOD# 869.
S
p
e
c
S
p
e
c
Phone Power:
voltage, with a minimum loop current of 20mA. Loop current may be
boosted on low current lines with a Viking Model TBB-1B talk battery
booster (DOD# 632).
LDB-3 Control Module: 120V AC/12V DC 500mA, UL listed
adapter provided
Dimensions: 241mm x 299mm x 51mm (9.5" x11.75" x2")
Shipping Weight:
Mounting: Flush mount to Talk-A-Phone ETP towers, wall
mounts, boxes and pedestals
Environmental: -26°C to 54°C (-15°F to 130°F) with up to 100%
condensing humidity
Material: .125" (11 gauge) brushed Marine grade 316 stainless
steel
Connections: Color-coded wires with gel-filled butt connectors
E-1600A-TP-EWP
E-1600A-TP-EWP
E-1600A-TP2-EWP
E-1600A-TP2-EWP
ADA Emergency Phones for
t
i
c
e
t
i
c
e
Talk-A-Phone Applications
L
U
T
I
O
N
S
L
U
T
I
O
N
S
l
i
c
a
t
i
o
n
s
l
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
Telephone line powered. Minimum 24V DC talk battery
2.9 kg (6.4 lbs)
March 28, 2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E-1600A-TP-EWP and is the answer not in the manual?

Questions and answers

Summary of Contents for Viking E-1600A-TP-EWP

  • Page 1 No batteries are required. The E-1600A-TP-EWP and E-1600A-TP2-EWP are equipped with Enhanced Weather Protection (EWP) for outdoor installations where the unit is exposed to precipitation or condensation. EWP products feature foam rubber gaskets and boots, sealed connections, gel-filled butt connectors, as well as urethane or thermal plastic potted circuit boards with internally sealed, field-adjustable trim pots and DIP switches for easy on-site programming.
  • Page 2 Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 (715) 386-8666...
  • Page 3 A. Wiring Rear View of the E-1600A-TP-EWP Phone Panel 1600A Emergency Preparing the Power Supply Phone Board Step 1. Cut off the barrel connector. Step 2. Seperate the wires. Step 3. Connect 12V adapter wires to power supply wires on the LDB-3 Control Module using the supplied butt connectors and then plug in power supply.
  • Page 4 A. DIP Switches Sw 1 Description Sw 3 Ring Indication Only. Off-Hook/Loop Current Detection Only. Ring and Off-Hook/Loop Current Detection. Sw 2 Ring Cadence Mode (see section B) Ring Cadence Mode ON - strobe remains activated in between rings. Ring Cadence Mode OFF - strobe is activated only during ringing. 1.
  • Page 5: Speed Dial Numbers

    Step 5. When finished programming, move DIP switch 3 back to the ON position (see section J). Warning: Failure to do step 5 above will cause the 1600A Series to call Viking Technical Support instead of your programmed number. Note: If a valid memory position is entered, a double beep will be heard, four beeps indicate an error.
  • Page 6: Identification Number

    2. “INFO” Speed Dial Numbers (E-1600A-TP2-EWP only) (memory locations #07 - #09) The information speed dial number programmed in location #07 is the telephone or extension number that is dialed when the “INFO” button is first pressed. Additional information speed dial numbers will be dialed when there is no answer and the next number redial feature is activated.
  • Page 7 Touch Silence Tone Time Out Setting C - Silence Time Out Disabled 10 sec This feature selects the length of time that calls will remain connected without voice activ- 20 sec ity. Programmable in increments of 10 seconds up to a maximum of 90 seconds (Touch 30 sec 40 sec* Tones 1 - 9).
  • Page 8: Recording The Announcement

    CO line, or behind a "dial 9" PBX. The 1600A Series phone will first dial 9, and then listen for second dial tone; if detected it will continue to dial Viking’s assisted programming phone number. If a second dial tone is not detected, it then knows is not behind a PBX, so it will momentarily hang up and then directly dial Viking’s assisted programming phone number.
  • Page 9 (no security code required). Use this option if you have forgotten your security code. Any out- bound call will dial Viking Technical Support (see section I). 1 2 3 Warning: When finished programming, set this switch back to the ON position, otherwise the 1600A Series phone will only call Viking Technical Support instead of your programmed emergency number.
  • Page 10 d. Speed Dial Numbers The 1600A Series phone can be programmed to dial a central station receiver only, or dial up to 5 voice num- bers first, and if no answer, then dial the central station receiver. When calling the first numbers (memory posi- tions #00-#04 (see Programming section D), the phone stays in “two-way talk mode”...
  • Page 11: Standard Operation

    c. 4+1 Express Format This DTMF format consists of a four digit account code, two digit message type, and a single digit event code. XXXX 17 X #20 Account Code Memory Location Message Type Event Code Enter 4+1 Express ID Settings Here: d.
  • Page 12: Central Station Operation

    For more information on the 1600A Series Emergency Phones, retrieve DOD# 215. Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information.

This manual is also suitable for:

E-1600a-tp2-ewp

Table of Contents