D3. 4/2 Event Codes - Visonic PowerMaxComplete Installer's Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaxComplete:
Table of Contents

Advertisement

D3. 4/2 Event Codes

Note: The report to central station is on the following zones: First wireless siren - zone 31, second wireless siren - zone 32,
GSM - zone 33, first 2-way keypad (MKP-150/151/152/160) - zone 35, second 2-way keypad (MKP-150/151/152/160) -
zone 36.
Alarms
Zone #
1
2
3
4
st
1
digit
4
4
4
4
nd
digit 1
2
3
4
2
Restorals
Zone #
1
2
3
4
st
1
digit C C C C C C C C C C C C C C C D D D D D D D D D D D D D D D
nd
2
digit 1
2
3
4
Supervisory trouble
Zone #
1
2
3
4
st
6
6
6
6
1
digit
nd
digit 1
2
3
4
2
Low Battery
Zone #
1
2
3
4
st
1
digit
8
8
8
8
nd
2
digit 1
2
3
4
Forced Arming – 8 users
User No.
1
st
1
digit
A
nd
2
digit
1
Zone Bypass
Zone #
1
2
3
4
st
1
digit A A A A A A A A A A A A A A A B B B B B B B B B B B B B B B
nd
2
digit 1
2
3
4
Panic / 24 Hours - 8 users
User No.
1
st
1
digit
2
nd
2
digit
1
Arm HOME and AWAY (Closing)
User No.
1
st
1
digit
E
nd
2
digit
1
Disarm (Opening)
User No.
1
st
1
digit
F
nd
2
digit
1
Trouble
Event
Fuse
Fail
Restore
st
1
digit
2
nd
2
digit
C
Event
CP Tamper
Restore
st
1
digit
nd
2
digit
D-303983 PowerMaxComplete Installer's Guide
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
4
4
4
4
4
4
4
5
6
7
8
9 A B C D E F
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
5
6
7
8
9 A B C D E F
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
6
6
6
6
6
6
6
5
6
7
8
9 A B C D E F
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
8
8
8
8
8
8
8
5
6
7
8
9 A B C D E F
2
3
4
5
A
A
A
A
2
3
4
5
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
5
6
7
8
9 A B C D E F
2
3
4
5
2
2
2
2
2
3
4
5
2
3
4
5
E
E
E
E
2
3
4
5
2
3
4
5
F
F
F
F
2
3
4
5
Fuse
Jamming Jamming
Restore
2
2
D
E
No Active
1
1
7
8
4
4
4
4
5
5
5
1
2
3
1
2
3
6
6
6
6
7
7
7
1
2
3
8
8
8
8
9
9
9
1
2
3
6
7
8
A
A
A
6
7
8
1
2
3
6
7
8
Panic CP
2
2
2
2
6
7
8
9
6
7
8
Cancel alarm
E
E
E
E
6
7
8
9
6
7
8
F
F
F
6
7
8
AC
AC
Failure
Restore
2
1
1
F
1
2
COMM. &
Enter Test
LINE Restore
1
A
5
5
5
5
5
5
5
4
5
6
7
8
9 A B C D E F
4
5
6
7
8
9 A B C D E F
7
7
7
7
7
7
7
4
5
6
7
8
9 A B C D
9
9
9
9
9
9
9
4
5
6
7
8
9 A B C D
4
5
6
7
8
9 A B C D E F
Duress
2
A
Recent Close
E
C
CPU Low
CPU Low
Battery
Battery Restore
1
1
3
4
Exit Test
Auto Test
1
1
D
E
5
5
5
5
5
7
7
7
9
9
9
CP
Tamper
1
6
1
F
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents