S N O M
wanted packet address is not in the current subnet. Setting up this
parameter is mandatory in order to reach an external network.
dhcp
Valid values:
<dhcp>, <off>
Default:
dhcp
Description:
Use DHCP (<dhcp>) or do not use DHCP (<off>).
time_server
Valid values:
e.g. <192.53.103.103>
Default:
SIP: Blank, H323: 192.53.103.103
Description:
Address of the time server. If the SIP proxy is offering the
time during a registration, the time will be set to this value. In such a
case a time server is not needed.
utc_offset
Valid values:
e.g. in Germany it is <+3600>.
Default:
Blank
Description:
Signed UTC offset in seconds.
dst
Format:
offset mm.ww.dd hh:mm:ss mm.ww.dd hh:mm:ss
Valid values:
e.g. for Germany <3600 03.05.07 02:00:00 10.05.07 03:
00:00>
Default:
Blank
Description:
Daylight saving time that observes yearly change and leap
years.
ntp_server
Valid values:
e.g. <192.53.103.103>
Default:
192.53.103.103
Description:
Address of the NTP time server.