Front-Panel Key Reference

Source Amptd

Source Amptd

Source Amptd
1DN or 1DQ only) Without Option 1DN or 1DQ, pressing
will cause the error message "Required option not installed" to
appear on the analyzer display.
activates (
Amplitude On Off
generator. The power level can then be adjusted using the numeric
keypad, step keys, or knob. Pressing any digit, 0 through 9, on the
numeric keypad brings up the selected terminator menu. See
specifications and characteristics in Chapter 9 for the available output
power for your tracking generator. Key Access:
activates (
Power Sweep On
Off
of the power-sweep range is displayed in the active-function block when
Power Sweep On Off
specified frequency range when power sweep is on. (To do a power
sweep at a fixed frequency, set the analyzer to zero span at the desired
frequency). The available power-sweep range is a function of the source
attenuator setting. See "Specifications" for the available power sweep
range.
The output power of the tracking generator is swept according to the
sweep rate of the spectrum analyzer. The output power is always swept
from the source power setting to a higher power setting (negative
source power sweep values are not allowed).
Power-sweep measurements are particularly useful in making gain
compression measurements or output power versus frequency
measurements. Key Access:
allows you to select between automatic and manual adjustment of the
Attenuation Auto
Man
tracking generator's switching attenuator. The HP ESA-L1500A can be
manually adjusted from 0 to 60 dB in 10 dB steps. When auto-coupled,
the attenuation function automatically adjusts the attenuator to yield
the source amplitude level specified by the
function. Set
(decoupled) for power sweeps greater than 10 dB.
Key Access:
allows the user to set the step size of the power level, power offset, and
Amptd Step Auto
Man
power- sweep range functions of the tracking generator. The default
setting is one vertical scale division. Key Access:
100
accesses the tracking generator key functions. (Options
) or deactivates (
On
Off
) or deactivates (
On
Off
is set to
On
Source Amptd
Attenuation Auto Man
Source Amptd
) the output power of the tracking
Source Amptd
) the power-sweep function. The value
. The analyzer continues to sweep the
Amplitude On Off
so that Man is underlined
Source Amptd
Source Amptd
softkey
Chapter 4