Figure 5-2 Rear Panel Features - Agilent Technologies 11713A Operating And Service Manual

Attenuator/switch driver
Table of Contents

Advertisement

Local Operation
Local Control

Figure 5-2 Rear Panel Features

[1] ATTEN X
Connector to accept cable plug going to
programmable attenuator X
[2] ATTEN Y
Connector to accept cable plug going to
programmable attenuator Y
[3] S9 A,B
Banana jack connectors for hook up to the
coaxial switches
[4] 24 Vdc
Banana jack connector provides the common
connection for the +24 Vdc used to drive the
coaxial switches.
[5] S0 A,B
Banana jack connectors for hook up to the coaxial
switches
[6] Window
Safety interlock; fuse cannot be removed while
power cable is connected to power receptacle
[7] Fuse Pull Handle
Mechanical interlock; fuse must be removed
before extraction of Line Voltage Selection Card
5-4 11713A Operating and Service Manual
[8] Fuse
1.25 A at 110/120 Vac; 750 mA at
220/240 Vac
[9] Line Voltage Selection Card
Matches transformer primary to line
voltage
[10] Receptacle
Matches transformer primary to line
voltage via power cable
[11] Line Power Module Assembly
[12]
This symbol is used to point out a
necessary reference for the user.
[13] GPIB Address
Switches to set the address of the
driver (decimal 28 is factory preset)
[14] GPIB Connector
The interface connector from a
source device to a listening device for
the remote mode of operation