*RST

Comments

*SAV

Parameters
Comments
424
Command Reference
*RST
resets the Agilent E1445A as follows:
Sets all commands to their
Aborts all pending operations including waveform generation.
does not affect:
*RST
The state of VXIbus word serial protocol
The output queue
The Service Request Enable Register
The Standard Event Status Enable Register
The enable masks for the Operation Status and Questionable Signal Registers
Calibration data
Calibration security state
Protected user data
The DAC code format (signed vs. unsigned)
Waveform segment, segment sequence, and frequency list definitions
Executable when Initiated: Yes
Coupling Group: None
*RST Condition: None
*SAV <
number
>
stores the current programming state into one of the 10 possible stored
state areas. The
number
<
This command stores the states of all commands affected by
include the DAC code format (signed vs. unsigned), the
including waveform segment, segment sequence, and frequency list definitions, the
subsystem commands, and the
STATus
Parameter
Parameter
Name
number
numeric
<
>
Executable when Initiated: Yes
Coupling Group: None
*RST
state.
indicates which of the stored state areas should be used.
>
CALibration:SECure
Range of
Type
0 through 9
. Notable exceptions
*RST
[SOURce:]LIST
commands,
command state.
Values
Chapter 8
Default
Units
none