Follett 110CR400A/W Installation, Operation & Service Manual page 13

110 series ice and water dispensers
Table of Contents

Advertisement

2. Remove dispenser top front cover by removing two screws at bottom corners of cover, lifting cover slightly and pulling
forward.
3. Remove icemaker compartment top and side panels.
4. Remove icemaker hold-down bracket from front of icemaker compartment.
5. Lift icemaker onto dispenser top and slide icemaker completely into position, compressor end first. Front of icemaker
base must be flush with front of dispenser.
6. Reinstall hold down bracket on front of icemaker with power cord and bin signal cords in notch. Do not cut or pinch
cords.
7. Insert loose end of ice transport tube through bracket (on icemaker base) into hopper access hole. Be sure that transport
tube is secured under retainer on float reservoir bracket (Step 2, Fig. 7). Tighten transport tube clamp screw to secure ice
transport tube.
8. Connect plastic water supply line to fitting at top of float reservoir.
Fig. 7 – Ice transport tube
1
9. Connect vinyl drain line from dispenser securely to drain line on icemaker.
10. Connect icemaker two-lead bin signal twist lock plug, and three-lead power twist-lock plug, to dispenser twist-lock
connectors.
11. On dispensers equipped with water-cooled icemakers, connect condenser water supply and drain lines to condenser
fittings on icemaker.
12. Turn on water supply and check that water level in float reservoir (when full) is within 1/4" (6mm) of mark on side of
reservoir and that float moves freely.
13. Verify that water sensor tabs are immersed in water in reservoir. Check for leaks. Replace splash panel.
14. Plug dispenser power cord into 20 amp rated NEMA 5-20 wall socket.
15. If dispenser is equipped with SensorSAFE remove protective plastic coating form dispense sensor labels.
16. Turn on power and bin signal rocker switches and test operation.
17. Clean and sanitize icemaker following instructions in icemaker manual.
18. Remove dispenser hopper access lid and clean and sanitize dispenser according to instructions on page 14.
19. Replace front cover and secure with screws. Installation is complete.
Fig. 8 – Ice transport tube and ice level control stat mounting for units with top-mounted icemakers
ice level control stat
2
.75"
(19mm)
45°
13
TIGHTEN
CLAMP
3
SCREW
Hand bend cap tube
end to approximately
45° as shown

Advertisement

Table of Contents