( Access on Aux. Output ) into the Aux. 1 or Aux. 2 option locations. Also program the option Access Control on Auxiliary Output ,
and a time into the Auxiliary Output Access Control duration. If an Access Control from the keypad is desired, also program a Panel
Access Code.
KeyFob Disarm Activates Entry Lighting
Disarming with a KeyFob can activate Remote Relays or X-10 Devices by programming the event EntryRelay Area1, or EntryRe-
lay Area2 on the External Relay Control screen. This event will cause the programmed outputs to activate on either a KeyFob Disarm
OR the opening of the Exit Entry zone while the system is armed.
Keypad Access See Access Control
Keypad Area Assignments
In multiple-area systems, assign an Area Number ("1" or "2") to each keypad.
Keypad Features
The following programmed system features will activate only if they have also been enabled at the keypad.
Ambush
Easy Arming
Access Control
Keypad (Police) Panic
Keypad Auxiliary Panic
Keypad Fire Panic
Keypad Panic See Panic Zone
Keypad Panic See Panic Zone
Keypad Sounder on Alarm
If a programmed zone goes into alarm, the keypad sounder will activate and will remain activated until the
pressed or the system is disarmed.
Keypad Tamper See Tamper
Keyswitch Arming
The area will arm/disarm when the programmed zone is momentarily shorted (momentary keyswitch). To supervise the key-
switch, program the zone for Day Zone on Open.
Leading Digits for Pager Format
In Pager Format reporting, the message typically begins with 00. With some pager services, this will cause the Pager's Voice
Mail feature to activate. Program these digits to any number desired. Typical Pager report - 003 022 1234, where 3 is the Event, 22
is the zone, and 1234 is the Subscriber ID number.
If the Leading Digits are programmed as 98 (1
the Pager report will now appear as 983 022 1234.
Line-Reversal Module, M278
The Line-Reversal Module allows the panel to be monitored by a central station through leased lines. On alarm, the module re-
verses normal line-voltage polarity. For details, refer to the instructions furnished with the module.
Logging of Security Bypassed Zones
The panel will log by User, Date, Time, and Zone any zones which are bypassed with the Security Bypass Mode. This is useful
in a system where openings are on 24 hour protection zones and access is only allowed if the zone is Bypassed by an authorized
User, and then Unbypassed when done. A typical application would be a warehouse or shipping terminal where the overhead doors
are programmed for 24 hour protection and must be Bypassed to allow access, and then Unbypassed again.
To activate this feature, DO NOT program Disable Code Required for EZ Bypass is Program BE (Bypass Enable) for each user
who is to have this ability.
To Security Bypass a zone:
To Security Unbypass a zone, follow the same procedure. When the zone # is entered (step 4), the display will read
"
UNBYPASSED ZONE #
To Arm/Disarm the system without altering the state of Bypassed zones, program the option Disable Auto-Unbypass on
Disarming. (Address Location 2417 = [4][ ])
It is not possible to Bypass/Unbypass Zones using the Directory Mode procedure.
Typically, any zone, other then a fire zone, will automatically be unbypassed when the panel is disarmed. In order to unby-
pass a fire zone, follow procedures 1 through 4. After executing step 4 the display will read - Unbypassed, Zone #.
X
GEM-P3200 Installation Instructions
digit = Address Location 0520 [ ] [9], 2
st
1. Enter Arm/ Disarm code * Code must be Bypass Enabled
2. Press the
B
3. Press the
B
4. Enter the zone #. The display will read, "
5. To bypass another zone, repeat steps 3 and 4.
".
digit = Address Location 0521 [ ] [8]),
nd
button. The display will read, "
button, again.
BYPASSED ZONE #
L
WI817F 10/05
C
button is
BYPASS ENABLED
".
"