WI817F 10/05
DISPLAY OP/CL
NAPCO's PCD-Windows Quickloader software offers a comprehensive array of programmable opening and clos-
ing suppression windows, by area, for all days of the week, for both normal and holiday schedules. A two-line dis-
play of the programmed schedule may be read at the keypad. The first line indicates:
the day of the week
opening or closing suppression window
"AUTO", if autoarming
normal (or delayed) schedule (see below)
To scroll through the days of the week, use the NEXT and PRIOR buttons.
The closing of any suppression window may be delayed up to four hours at the keypad, or the window may be totally dis-
abled, up to one week in advance. Select the DAY/OP/CL schedule using the NEXT and PRIOR buttons. Select the delay (1-
4 hours) or disable using the
see Autoarm Function. (Autoarming can be disabled or delayed by area using PCD-Windows software).
ACTIVATE OVERVIEW
This mode provides a system status display of all partitioned areas at a glance. Note: The keypad selected for the Over-
view Mode will remain in that mode. To convert the keypad back to its original use as an area keypad, enter the Function
Mode and access DEACTIVATE OVERVIEW. The display will revert to "SYSTEM READY". Also see Overview Mode.
ACTIVATE CHIME *
Press YES button to sound a tone at the keypad when a Chime Zone is violated. The duration of the tone is programma-
ble. To turn off the Chime Mode, press YES button at the DEACTIVATE CHIME function. *Note: Chime and Watch modes
display as "Monitor" on all GEM-RP2ASe2 and GEM-K2AS keypads.
ACTIVATE WATCH*
This option, if programmed, permits all zones designated as Day Zones to be turned on. When selected, a "W" will appear
in the display (GEM-RP1CAe2 only) as long as the Watch Mode is active. To deactivate the Watch Mode, arm, then disarm.
*Note: Chime and Watch modes display as "Monitor" on all GEM-RP2ASe2 and GEM-K2AS keypads.
RESET SYSTEM TRBL
System troubles normally latch and display and sound at the keypad. Pressing the
sounder; "SYSTEM READY" will be displayed. Correcting the trouble will clear most system trouble indications, however
the following system troubles require a Level-2 or -3 code for manual reset (enter code; access RESET SYS TRBL
U
then press the
EZM Tamper
Keypad Tamper
Sensor Watch
Service Reminder
Note: (1) If a system trouble is not corrected, it will redisplay after 5 minutes. (2) If one or more of the foregoing system
troubles appear during the first 5 minutes after power-up, they will be cleared automatically.
RESET SENSOR MSG
Press YES button to reset a PIR Supervision system trouble.
START EXIT TIME
If the central station ringback signal has not been received within about 30 seconds, a communication problem may exist.
Press YES button to start exit delay manually.
FAULT FIND
This troubleshooting aid will help the installer locate swingers. When accessed, two things occur:
The loop response of each zone is set for the fastest response time.
Causing or repairing a fault activates the sounder for about 7 seconds.
Tapping and poking at suspect points, the installer can easily locate swingers by listening for the beep. This eliminates the
need of returning to the keypad to visually check after each attempt. Pressing the
Arming the system automatically cancels the Fault find Mode. Note: When testing wireless systems, the keypad will not beep
if the signal strength is less than 3, but the strength will still be displayed.