NAPCO Gemini GEM-P3200 Installation Instructions Manual page 41

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P3200:
Table of Contents

Advertisement

WI817F 10/05
indicating that only partial protection will be provided upon arming. To temporarily restore interior protection, press
"
BYPASS
" reminder will go out upon arming, denoting full protection, however Interior (Stay) Zones will once again be bypassed the
next time the panel is disarmed.
If "Auto Interior Bypass" is programmed, all Interior Zones will automatically be bypassed if the Exit/Entry doors are not opened during
D
exit delay. If
is pressed while armed Stay, exit delay will restart and Exit/Entry doors may be opened to permit someone to exit
(while others remain on premises) without causing an alarm.
Interior (STAY) Bypass
(Applies to "GEM-RP" keypads only). "Interior (Stay) bypass" zones allows freedom of movement inside the premises, while still pro-
viding perimeter partial protection, in ARMED STAY mode by pressing
Zones) are all protected with full protection, in ARMED AWAY mode, by arming without the perimeter button. The next time the zone
is disarmed, the zone will become a full protected zone. Interior zones can be made to be normally bypassed by enabling "Interior
Normally Bypassed" and to be unbypassed by pressing
protected zone.
Jumpers (Refer to Wiring Diagram for UL configuration.)
A: Cut for dry contacts on the Auxiliary Relay.
B: Cut for dry contacts on the Burglary Relay.
C: Cut for dry contacts on the Reset Relay.
D: Cut if using a PS3002 Power-Supply Module.
JP5: Keypad Configuration Jumper (top-right corner, above micro shield) is installed across top and center pins for normal op-
eration. When configuring the GEM-RP1CAe2 and GEM-K1CA keypads, move jumper across center and lower pins.
JP6 & PS: For Residential Fire. See Alarm Outputs.
JP7: 2-Wire Fire jumpers. Select Zones 7 and/or 8 for use as either 2-Wire Fire Zones or Burglary Zones. Note: If customizing
a single-area default program, Zone 8 is configured as a 2-Wire Fire Zone. In a two-area default program, Zones 7 and 8
are configured as 2-Wire Fire Zones common to both areas; be sure to move JP7 Zone-7 jumper to the 2-WF position (see
Wiring Diagram).
Keypad Digital Dialer Test
A Digital Dialer Test (Central Station Comm. Test) can be initiated from the function menu. Press
TEST Y/N" is displayed and then press [NEXT/YES] to initiate the transmission of a Test Timer signal. Note: Test Timer reporting
codes and Report Test Timer on Telco1 or Telco 3 must be programmed.
Keypad Jumpers: GEM-RP1CAe2 (and GEM-K1CA) (Refer to label LA1374 on the circuit board fishpaper for jumper locations and
a summary of settings)
JP1: Cut to enable Keypad Tamper.
W1 & W3: Cut both to disable touchpad backlighting.
W2: Cut to disable LCD backlighting.
Keypad Jumpers: GEM-RP2ASe2/RP3DGTL (Refer to label LA1390 on the circuit board fishpaper for jumper locations and a sum-
mary of settings)
See Section 3: Configuring the GEM-RP2ASe2/GEM-RP3DGTL Keypad for jumper selection.
Key Fob Transmitters
AuxOut Chirp on Key-Fob Arm/Disarm
Select Bus Output for Key-Fob Chirp
Disable AuxOut Clear on Disarm
AuxOut Chirp on Key-Fob Arming will cause one 50 mS chirp to sound on arming and two 50mS chirps on disarming. Use the
steady output of a siren driver. Do not use a voice siren driver.
Burg Output Chirp on Key-Fob Arming will cause one 50 mS chirp to sound on arming and two 50mS chirps on disarming. Use
the steady output of a siren driver. Do not use a voice siren driver.
Programming a "C as the Key-Fob Aux-1 or Aux-2 option will provide the ability to toggle the Aux. Relay on or off. If there is an
Aux. Relay timeout programmed, it will follow this timeout unless toggled off by the key fob. To provide key-fob-only control, program
no timeout. Program Disable AuxOut Clear on Disarm to prevent a disarm from resetting the Aux. Relay.
Key-fob users can report openings and closings. Key fobs 1–8 report as Users 25–32, respectively.
Keyfob Zone Assignment
Keyfobs can be assigned to zones to allow individual reporting. Each of the 4 keyfob buttons can be assigned to a zone. For
example, On button = point 1; Off button = point 2; A1 = point 3; A2 = point 4. Up to 48 keyfobs can be assigned to the GEM-P3200,
providing multiple wireless panic buttons on a system, each reporting to the Central Station or a pager and/or annunciating on a key-
pad the keyfob zone number with description/location. To assign a keyfob to a zone, program the keyfob as you would a transmitter,
entering the keyfob's ID code, check sum and point number at the appropriate zone.
KeyFob or Keypad Garage Door opener control
The Auxiliary Relay can be programmed to activate for a programmable period of time. This allows it to be used for access func-
tions such as opening and closing a garage door. This is achieved through a new KeyFob option, Access control, by programming
L
NAPCO Security Systems
E
before arming. All zones (including Interior Bypass
E
. The next time the zone is armed, the zone will become a partially
X
until "DIGITAL DIALER
R
GEM-P3200 Installation Instructions
Page 41
; the
E

Advertisement

Table of Contents
loading

Table of Contents