NAPCO Gemini GEM-P3200 Installation Instructions Manual page 39

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P3200:
Table of Contents

Advertisement

WI817F 10/05
Enable Burg Output Warning On Entry
Causes the Burglary Output to "chirp" if the entry door is opened within 60 seconds after exit time has elapsed. This feature may
be useful in cases where a keypad is not within audible range to remind a user to disarm if inadvertently exiting after exit delay has
expired.
Enable CP-01 Limits
(SIA CP-01 Requirement: 4.2.5.1)
When address 3905 bit 5 is enabled, three time limits are enabled as per the SIA CP-01 standards: (1) Exit Delay Time: If an at-
tempt is made to change the Exit Delay time to less than 45 seconds the time will be entered as 60 seconds. The maximum pro-
grammable time is 255 seconds; (2) Entry Delay: If an attempt is made to change the Entry Delay time to less than 30 seconds the
time will be entered as 30 seconds. The maximum programmable time is 255 seconds; and (3) Abort Delay: If an attempt is made to
change the Abort Delay to less than 15 seconds or more than 45 seconds the time will be entered as 30 seconds.
NOTE: In accordance with UL standards, the aggregate of the Entry Delay time and Abort Delay time "window" will not be pro-
grammed to exceed one minute. Note: When Address 3905 bit 5 "Enable CP-01 Limits" is enabled, the Exit Delay keypad sounder
(including the Exit Urgency sound during the final 10 seconds of the Exit Delay) is enabled. Note: If "Enable CP-01 Limits" is en-
abled in EZ Programming, any Zone in a Group will only activate an alarm and send a report ONCE. After the Zone has reported, it
will remain in the Group and may still initiate the Zone ANDing sequence.
Enable Exit Delay Restart
This option allows for the following scenario prior to the end of the Exit Time: a violation of an entry/exit zone, a restore, and a
second violation of an entry/exit zone restarts the Exit Time. The panel does not allow the Exit Time to be restarted more than once.
The default setting for this option is enabled. Restart events are logged. (SIA CP-01: 4.2.2.3).
Enable Point ID Open/Close as Code 402
Program to send a "402" closing code (for Ademco Point ID modem format) in place of a "401" code.
Enable Telephone Line Fault Test
Telephone Line Test Delay
Enable Telephone Line Fault Test will cause the panel to monitor the phone line. A failure will display as "E08-00 TELCO LINE1 FAIL".
Program this system trouble to activate the Burglary Output.
If a time is entered in Telco Line Test Delay, the line will be tested for the programmed time before a system trouble is activated.
A minimum of 30 seconds is recomm
Enable Set Time/Date Message
In the event of a memory corruption, the loss of the system clock will occur and a message 'SET TIME / DATE" will be displayed
on the GEM-RP1CAe2 keypad. The message will remain until the Time and Date have been re-programmed.
Enable Local Alarm on First Zone "AND" Trip See Zone ANDing (Do not program in UL installations.)
Enable Reporting to PC Preset
This feature allows a PC computer with Quickloader Software to function as a receiver. If programmed, all alarms sent to Tele-
phone No. 1 will be sent to PC PRESET as well (regardless of whether or not transmissions to Telephone No. 1 were successful).
PC PRESET must be in its Standby mode for this feature to operate.
Enable User Code by Area See User Codes/Authority Levels/Access Bytes
Entry/Exit Delay
Entry/Exit 1; Entry/Exit 2
Entry Relay
Enable Exit-Delay Restart
Delays permit exit and entry through the Entry/Exit Zone(s) after the system is armed without setting off an immediate alarm.
Entry delay allows the user time to enter and disarm the panel. Exit delay allows the user to leave the premises after the panel has
been armed. Unless the keypad has been configured otherwise, the sounder will come on and will pulse during the last 10 seconds
of entry delay to remind the user to disarm.
Two individually-programmable entry-delay times are provided to accommodate different entry zones. If two or more Exit/Entry
Zones are entered in succession, the delay programmed for the last Exit/Entry Zone entered will take precedence over all others.
Exit-Delay time and Entry-Delay time may each be programmed for up to 255 seconds (4 minutes). See Time Selection.
An external relay may be programmed to trip upon entry (see Programming Manual: Relay Event ID Codes, Area Entry Relays),
and remain on for a programmed duration.
If the system has been armed with Exit-Delay Restart enabled, when the exit door is opened and then closed, the programmed
exit delay will restart at 60 seconds. Thus, if a long exit delay is programmed, it will be reduced to 60 seconds after exiting, yet still
allow reentry before entry time starts. If re-entry occurs within that 60 seconds, exit delay will restart once again (and only once
again) at 60 seconds.
If re-entry occurs within 60 seconds after exit delay has expired, the alarm will sound a 2-second warning (with the entry
sounder) to remind the user to disarm. (Exit-Delay Restart may be useful in reducing false alarms caused by a user who re-enters
the premises shortly after exiting.)
Note: In UL installations, maximum exit delay is 60 seconds; maximum entry delay is 45 seconds. In UL Mercantile installa-
tions, maximum entry delay is 60 seconds.
L
NAPCO Security Systems
ended.
X
GEM-P3200 Installation Instructions
Page 39